Shanghai Huile Electric Co., Ltd
Home>Products>Single-phase power meter
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    1881753568318321031365
  • Address
    No. 95 Shihuxin Road, Shihudang Town, Songjiang District, Shanghai
Contact Now
Single-phase power meter
The full-scale display value, upper and lower limit alarm values, and communication address can be freely set through the buttons on the panel, making
Product details
  • Single-phase power meter
  • The full-scale display value, upper and lower limit alarm values, and communication address can be freely set through the buttons on the panel, making it very flexible and convenient to use.
    ● Optional analog transmission output, 4-20mA, 0-20mA, 4-12-20mA, 0-5V, 1-5V optional.
    ● Optional 2-channel alarm output for monitoring the upper and lower limits of the measured parameters.
    Optional RS485 digital interface, using standard MODBUS RTU protocol.

    Adopting direct communication RMS effective value measurement, digital zero calibration, digital tuning, high accuracy, and extremely high cost-effectiveness.


    Detailed Introduction




    overview
    The full-scale display value, upper and lower limit alarm values, and communication address can be freely set through the buttons on the panel, making it very flexible and convenient to use.
    ● Optional analog transmission output, 4-20mA, 0-20mA, 4-12-20mA, 0-5V, 1-5V optional.
    ● Optional 2-channel alarm output for monitoring the upper and lower limits of the measured parameters.
    Optional RS485 digital interface, using standard MODBUS RTU protocol.
    Adopting direct communication RMS effective value measurement, digital zero calibration, digital tuning, high accuracy, and extremely high cost-effectiveness.
    TECHNICAL INDEX
    transport
    enter
    measure
    measure
    apparent
    show
    electricity
    press
    RATING AC100V, 400V (special customizable)
    overload Duration: 1.2 times Instantaneous: 2 times/10 seconds
    power consumption < 1VA (per phase)
    accuracy RMS measurement, accuracy level 0.5
    electricity
    flow
    RATING AC 1A, 5A (please specify when ordering)
    overload Duration: 1.2 times Instantaneous: 10 times/10 seconds
    power consumption < 1VA (per phase)
    accuracy RMS measurement, accuracy level 0.5
    power Active power accuracy level 0.5, reactive power accuracy level 1.0
    power supply scope of work AC 220V ± 20% Special requirements can be customized
    power consumption <5VA
    output Digital Interface RS-485, MODBUS-RTU protocol (optional)
    Switching Output Switch output, relay passive contact mode (optional)
    analog output Analog transmission output, 4-20mA/0-20mA/4-12-20mA/0-5V/1-5V (optional)
    environment work environment -10-55 ℃, relative humidity<85%. Non corrosive gas environment, altitude<2000m
    Environment -55-85 ℃, relative humidity<85%
    secure pressure resistance Power supply/output>1KV
    isolation Input, output, and power supply to the chassis>100M Ω


    List of Models and Sizes for Single phase Active Power Meter Series
    model measure display Appearance and installation dimensions Peripheral functions (optional, to be specified when ordering)
    A B C D E digital communication Switch Module Transmission output
    HL-42XP Single-phase active power

    LED

    120 120 73 112 112 RS-485 2DO
    HL-96XP Single-phase active power LED 96 96 65 92 92 RS-485 2DO
    HL-80XP Single-phase active power

    LED

    80 80 67 76 76 RS-485 2DO
    HL-72XP Single-phase active power

    LED

    72 72 67 68 68 RS-485 2DO
    HL-45XP Single-phase active power LED 48 48 79 45 45
    HL-48XP Single-phase active power LED 49 97 66 91 45 RS-485 2DO

    List of Models and Sizes for Single phase Reactive Power Meter Series
    model measure display Appearance and installation dimensions Peripheral functions (optional, to be specified when ordering)
    A B C D E digital communication Switch Module Transmission output
    HL-42XQ Single-phase reactive power

    LED

    120 120 73 112 112 RS-485 2DO
    HL-96XQ Single-phase reactive power LED 96 96 65 92 92 RS-485 2DO
    HL-80XQ Single-phase reactive power

    LED

    80 80 67 76 76 RS-485 2DO
    HL-72XQ Single-phase reactive power

    LED

    72 72 67 68 68 RS-485 2DO
    HL-45XQ Single-phase reactive power LED 48 48 79 45 45
    HL-48XQ Single-phase reactive power

    LED

    49 97 66 91 45 RS-485 2DO
    HL-46XQ Single-phase reactive power

    LED

    60 120 72 116 56 RS-485 2DO

    Order List
    When placing an order, please specify in detail the required model, input signal ratio, and expansion function module.
    Example 1: Model: HL-48XP Power Supply: AC220V Input: AC220V AC5A
    Communication: RS485/MODBUA-RTU Alarm: 2 channels Quantity: 88 units



Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!