Speed area open channel ultrasonic flowmeter
Speed area open channel ultrasonic flowmeter
Product details

Speed area open channel ultrasonic flowmeter

overview
JD-900V seriesVelocity area open channel flowmeterIt is an instrument used to measure the flow rate of liquid in channels with non full pipes and open discharges. It can be widely applied in industries such as chemical, power, metallurgy, mining, and water conservancy. Production and testing standards are based on national standards《velocity-type flowmeter》Verification regulation JJG198-1994.
answer Use particular Point it
There are no special requirements for the cross-sectional shape and size of urban water supply channels.
Sewage treatment inflow and discharge channels can be installed and maintained without stopping water supply.
● Chemical liquid and wastewater discharge channels in industrial and mining enterprises ● Non obstructive flow, no head loss.
● Channels for water conservancy engineering and agricultural irrigation ● When the cross-section of the channel is large, multi-channel velocity measurement is used to achieve high-precision measurement.
● Flood discharge gate flow measurement ● It can measure the flow and velocity in both forward and reverse directions.
● Large measurement range and high accuracy.
● Can be used in trough weir or other waysOpen channel flowmeterCalibration equipment.
Working principle
Using the ultrasonic velocity difference method (the velocity difference caused by the propagation of ultrasonic waves in the direction of liquid flow and in the opposite direction) to measure the average flow velocity V of the liquid, and the level gauge to measure the depth H of the liquid level, when the cross-sectional shape and size of the channel are determined, the liquid flow rate Q in the channel can be calculated. Q=V × H × S (H), where S (H) is the functional relationship between liquid level depth and water flow cross-sectional area.
flow converter
By transmitting and receiving ultrasonic signals, the liquid flow velocity is measured using the principle of ultrasonic velocity difference method.
Receive signals from the liquid level gauge and calculate the liquid level depth based on the set liquid level range.
Calculate the instantaneous flow rate and cumulative flow rate of the liquid based on the cross-sectional shape and size of the channel set in the menu
Chinese display and Chinese operation menu
Data recording and storage
Before being searchable720Hours ago365Oh my god, before36Monthly and ten-year traffic data.
signal output
420mA,Accumulated quantity pulse,RS-485, can be connected (or embedded)GSM/GPRSThe module enables wireless data transmission and can be paired with printingMachine.
Ultrasonic velocity sensor
Ultrasonic velocity sensorIt is a device that realizes the mutual conversion of sound and electricity. When stimulated by electrical pulses, sound waves are generated, and when stimulated by sound waves, an electrical signal is output. Single channel has two sensors, dual channel has four sensors, and triple channel has six sensors. The sensor is fixed on the bracket and immersed in water. Our company's ceramic moldsUltrasonic velocity sensorIt is resistant to friction, corrosion, and has a long service life. It can work in water for a long time.
Liquid level meter
The liquid level is measured using ultrasonic echo ranging method, and this liquid level gauge is an intelligent non-contact liquid level measuring instrument. Equipped with automatic power adjustment, gain control, temperature compensation, advanced detection and calculation techniques to improve the measurement accuracy of the instrument, and suppression of interference echoes to ensure the authenticity of measurement results. The liquid level gauge is fixedly installed above the channel water level observation point.Probe the head and aim it vertically at the water surface.
power supply: DC24V
output: four20mA(four-wire system)RS485
range: 02m, 05m010m015m
control:Two way relay
accuracy: 0.25%
ambient temperature:- 25℃-55℃
protection grade: IP67
resolution: 1mm
Display mode: sixteenposition×2 LCDBacklight
Corrosion resistant integrated liquid level gauge
Installation hole size68mm
Shell material: high-strength engineering nylon(PA6 GF30
Static pressure level gauge
The static pressure level gauge consists of a pressure-sensitive element, a stainless steel housing, and a connecting cable. When the liquid density is constant, the liquid level height is proportional to the liquid pressure, and the liquid level height can be calculated by measuring the liquid pressure.
Measurement range: 02m05m010m 0100m(Cable type)
Accuracy level:0.5%
Medium temperature:-1070
Power supply levelDC 1632V
Signal output: 420mA(Two wire system)
Protection level:IP68
Shell material: stainless steel
Ultrasonic level gaugeNot in contact with the tested liquid, suitable for measuring sewage and corrosive liquids. The static pressure level gauge is immersed in the measured liquid and is suitable for measuring water quality with relatively pure solid particles.
mechanical components
The cross beam and sensor bracket are used to fix the ultrasonic velocity sensor and liquid level gauge, so that the sensor will not shake when the water flow impacts. The material of the crossbeam is generally channel steel or I-beam, and the material of the support is stainless steel. The structural form and size of the crossbeam and bracket should be determined according to the specific situation on site. The structure should be considered sturdy and should not be shaken by wind or water flow impact.
Installation
Ultrasonic velocity sensorInstallation of
Ultrasonic velocity sensorTo be installed in the straight channel section, the length of the straight channel should be greater than that of the channelwide3More than double.
Z method
The angle between the connection of each pair of sensors and the direction of water flow is300.
Straight line method
Clamp the connection between each pair of sensors and the direction of water flowThe angle is0.
Installation of liquid level gauge

Ultrasonic level gauge
Ultrasonic level gaugeShould be installed in the center of the channelAbove, ensure that the lowest point of the liquid level is measured. The highest waterThe distance from the bottom of the sensor to the surface should be greater than0.2m.
Static pressure level gauge
Static pressure level gaugeFix it on the bracket and place it in the water, and keep it away from the bottom of the canal20mmTo prevent sludge from blocking the pressure tapping hole.

Selection
Selection of Channel Number
Canal width less than3Meter, liquid level below2Mi Shi usually has a single channel; In other cases, choose two or three channels.
Selection of installation method for ultrasonic velocity sensor
Canal width less than3When it comes to rice, chooseZMethod; greater than3When choosing rice, choose the straight line method.
Selection of liquid level gauge
When there are fewer impurities and precipitates in the liquid and the liquid is non corrosive, a static pressure level gauge can be selected; Otherwise, it should be selectedUltrasonic level gauge.
Technical parameters

monoUltrasonic open channel flowmeter Dual channelUltrasonic open channel flowmeter Three channelsUltrasonic open channel flowmeter
Flow range
0-12m/s
Accuracy (%)
2
1.5
1.0
Measuring liquids
Water, sewage, and other liquids
signal output
1. 4-20mA: Impedance less than 500 Ω, optical isolation, accuracy of 0.1%.
2 RS-485: Optical isolation, optional baud rate, transmission distance greater than 1.6km.
3. Printer: Optional (wall mounted converter).
keyboard
Wall mounted: 2 x 8 Panel mounted: 16 key
monitor
2 x 10 Chinese characters display with backlight.
Measurement function
Traffic, speed, cumulative traffic, and running time.
Data storage
Can store data for the first 720 hours, the first 365 days, the first 36 months, and the first 10 years, including traffic and cumulative traffic.
ambient temperature
Converter:- 10~45℃
Ultrasonic velocity sensor:- 30~160℃
Ultrasonic liquid level sensor:- 20~45℃
Converter protection level Wall mounted sensors: IP65; Disk mounted sensor IP52;
Protection level of ultrasonic sensor
Ultrasonic velocity sensor: IP65; Ultrasonic liquid level sensor: IP52;
ultrasonic sensor
Cable type
Ultrasonic velocity sensor: SEYV75-2: RVVP3 x 0.3
Working power supply
AC: 220V ± 10% DC: 12-36V 1.5W
changeTransformer outer dimensionscun
Wall mounted: 213 x 185 x 107mm Pan mounted: 160 x 80 x 250mm
Ultrasonic velocity sensor
External dimensions
Ø 20 x 30mm fixed bracket size depends on the specific channel depth
Ultrasonic liquid level sensor
External dimensions
Height 205, width 115, thickness 120. Installation of hole nut M66 x 3
Converter weight
Wall mounted: 1.2k g Disk mounted: 1.0kg
Weight of ultrasonic velocity sensor 0.2kg
Weight of ultrasonic sensor
1.5kg

Selection code
For example, selecting a wall mounted converter, a three channel ultrasonic velocity sensor, and measuring the width and depth of the channel500mmWithout a printer.
Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!