Strong acid flowmeterWidely used in production process flow measurement and control in industries such as petrochemicals, steel metallurgy, water supply and drainage, water conservancy irrigation, water treatment, total control of environmental wastewater, papermaking, medicine, food, and other agricultural sectors; Suitable for measuring the total amount of conductive liquids.
No flow blocking components, no pressure loss or fluid blockage.
No mechanical inertia, fast response, good stability, can be applied to automatic detection, adjustment, and program control systems.
The measurement accuracy is not affected by the type of measured medium and its physical parameters such as temperature, viscosity, density, pressure, etc.
Different combinations of PTFE or rubber lining materials and electrode materials such as Hc, Hb, 316L, Ti can adapt to the needs of different media.
There are various flow meter models available, including pipeline type and plug-in type.
Using EEPROM memory, the storage of measurement and operation data ensures safety and reliability.
The accuracy level and function of the instrument are selected based on measurement requirements and usage scenarios to achieve cost-effectiveness. For example, in situations such as trade settlement, product handover, and energy measurement, higher accuracy levels such as 1.0, 0.5, or higher should be selected; For process control applications, choose different accuracy levels according to control requirements; In some cases where only the process flow rate needs to be detected without precise control and measurement, a slightly lower accuracy level can be chosen, such as 1.5, 2.5, or even 4.0,.
2. When measuring medium flow rate, instrument range, and caliber, the full flow rate of the flowmeter can be selected within the range of 0.5-12m/s for measuring medium flow rate, which is relatively wide. The selection of instrument specifications (caliber) may not necessarily be the same as the process pipeline, and should be determined based on whether the measured flow range is within the flow rate range. That is, when the pipeline flow rate is too low to meet the requirements of the flow instrument or the measurement accuracy cannot be guaranteed at this flow rate, the instrument port diameter needs to be reduced to increase the flow rate inside the pipeline and obtain satisfactory measurement results.
3. Try to avoid ferromagnetic objects and equipment with strong electromagnetic fields as much as possible to prevent the magnetic field from affecting the working magnetic field and flow signal of the sensor.
4. There should be ample space around for easy inspection and maintenance.
It is a volumetric flow measurement instrument that is not affected by the temperature, viscosity, density, and conductivity (within a certain range) of the measured medium during the measurement process.
The range is wide, up to 1:100. In addition,Strong acid flowmeterIt is only proportional to the average flow velocity of the measured medium, and is independent of the axisymmetric flow state (laminar or turbulent).
Strong acid flowmeterNo mechanical inertia, sensitive response, can measure instantaneous pulsating flow rate, and has good linearity. Therefore, the measurement signal can be directly converted linearly into a standard signal output using a converter. LD-T type can indicate on-site, while LD type can transmit over long distances.
Introduction:
It is developed based on Faraday's law of electromagnetic induction and is used to measure the volumetric flow rate of conductive fluids. Due to its unique characteristics, it has been widely used in the measurement of various conductive liquids in industry. Mainly used in industries such as chemical, papermaking, food, textile, metallurgy, environmental protection, and water supply and drainage, it can achieve system control when paired with computers.
There are no movable parts or flow barriers, which will not cause pressure loss, wear, blockage, or other issues.
Execution standards | JB/T 9248—1999 | ||||||
Nominal Diameter | 15. 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1200, 1400, 1600, 1800, 2000, 2200, 2400, 2600, 2800, 3000 | ||||||
velocity of flow | 15m/s | ||||||
accuracy | DNl5~DN600 | Indication: ± 0.3% (flow rate ≥ 1m/s); ± 3mm/s (flow rate<1m/s) | |||||
DN700—DN3000 | ± 0.5% of the indicated value (flow rate ≥ 0.8m/S); ± 4mm/s (flow rate<0.8m/S) | ||||||
Fluid conductivity | ≥5uS/cm | ||||||
nominal pressure | 4.0MPa | 1.6MPa | 1.0MPa | 0.6MPa | 6.3, 10MPa | ||
DNl5~DN150 | DNl5~DN600 | DN200~DN1000 | DN700~DN3000 | Special Orders | |||
ambient temperature | sensor | -25 ℃ -+60 ℃ | |||||
Converter and integrated model | -10 ℃ -+60 ℃ | ||||||
Lining material | Polytetrafluoroethylene, chloroprene rubber, polyurethane, perfluoroalkoxy (F46), mesh PFA | ||||||
Fluid temperature | - Body type | 70℃ | |||||
separated | Polychloroprene rubber lining | 80℃; 120 ℃ (specify when ordering) | |||||
Polyurethane lining | 80℃ | ||||||
PTFE lining | 100℃; 150 ℃ (specify when ordering) | ||||||
Perfluoroethylene propylene (F46) | |||||||
Mesh PFA | |||||||
Signal electrode and ground electrode materials | Stainless steel 0Crl8Nil2M02Ti, Hastelloy C, Hastelloy B, titanium, tantalum, platinum/iridium alloy, stainless steel coated with tungsten carbide | ||||||
Electrode mechanism | DN300—DN3000 | ||||||
Connecting flange material | carbon steel | ||||||
Strong acid flowmeterGrounding flange material | Stainless steel 1Cr18Ni9Ti | ||||||
import protection Flange Material |
DN65—DNl50 | Stainless steel 1Cr18Ni9Ti | |||||
DN200~DNl600 | Carbon steel and stainless steel 1Cr18Ni9Ti | ||||||
Shell protection | DNl5~DN3000 separable rubber or polyurethane lined sensor | IP65 or IP68 | |||||
Other sensors, body type flow meters, and separate converters | IP65 | ||||||
Distance (separated type) | The distance between the converter and the sensor is generally not more than 100m | ||||||
Electrode material | Corrosion resistance and wear resistance | ||||
stainless steel 0Crl8Nil2M02Ti |
Used for weakly corrosive media such as industrial water, domestic water, sewage, etc., suitable for industrial sectors such as petroleum, chemical, steel, as well as municipal and environmental protection fields. | ||||
Hastelloy B | It has good corrosion resistance to all concentrations of hydrochloric acid below boiling point, as well as to non chlorinated acids, bases, and non oxidizing salt solutions such as sulfuric acid, phosphoric acid, hydrofluoric acid, and organic acids. | ||||
Hastelloy C | Can withstand corrosion from non oxidizing acids such as nitric acid, mixed acids, or mixed media of chromic acid and sulfuric acid, as well as corrosion from oxidizing salts such as Fe, Cu, or other oxidants, such as hypochlorite solutions above room temperature and seawater corrosion | ||||
titanium | Capable of withstanding corrosion from seawater, various chlorides and hypochlorites, oxidizing acids (including fuming sulfuric acid), organic acids, and alkalis. Not resistant to the corrosion of relatively pure reducing acids (such as sulfuric acid, hydrochloric acid), but if the acid contains oxidants (such as nitric acid, Fc++, Cu++), the corrosion is greatly reduced. | ||||
tantalum | It has excellent corrosion resistance and is very similar to glass. Except for hydrofluoric acid, fuming sulfuric acid, and alkali, it can almost withstand corrosion from cutting chemical media (including boiling point hydrochloric acid, nitric acid, and sulfuric acid below 50 ℃). Dig in alkali; Corrosion resistance. | ||||
Platinum/titanium alloy | Almost capable of cutting chemical media, but not suitable for aqua regia and ammonium salts. | ||||
Stainless steel coated with tungsten carbide | Used for non corrosive and highly abrasive media. | ||||
Note: Due to the wide variety of media and the complex factors such as temperature, concentration, and flow rate that affect their corrosiveness, this table is for reference only. Users should make their own choices based on the actual situation, and if necessary, conduct corrosion resistance tests on the selected materials, such as hanging plate tests. | |||||
power supply | exchange | 85—265V,45—400Hz | |||
direct-current | 11—40V | ||||
Operation keys and display | Touch-tone | Four thin film buttons can be used to set and select all parameters, and the converter can also be programmed using a PC (RS232); 3-line LCD with wide viewing angle, wide temperature, and backlit display; The first line displays the traffic value; The second line displays the flow unit; The third line displays the percentage of traffic, total forward, total reverse, total difference, alarm, and flow rate. | |||
Magnetic key type | Two magnetic keys are used for selecting and resetting display parameters, and the converter is programmed using a PC (RS232); 2-line LCD display with wide viewing angle, wide temperature, and backlight: Line 1: Magnetic key selection: Display flow percentage, forward total amount, reverse total amount, difference total amount, alarm, and flow rate. Line 2: Display traffic. | ||||
Internal integrator | Positive total, negative total, and differential total. | ||||
Strong acid flowmeteroutput signal | Unidirectional analog output | Fully isolated, load ≤ 600D. (at 20mA); Upper limit: 0-21mA optional, 1mA per level; Lower limit: 0-21mA optional, 1mA per level; Programming for forward and reverse flow output modes. | |||
Bidirectional analog output | The lower limit is. Or 4mA, other same unidirectional analog outputs. | ||||
Bidirectional pulse output | Two outputs correspond to forward and reverse flow rates, with a frequency range of 0-800Hz and an upper limit of 1-800Hz to choose from. Each IHz level is available; Square wave or selected pulse width, with an upper limit of 2.5S and 1ms per level; Passive isolation transistor switch output, capable of absorbing 250mA current and withstanding 35V voltage. | ||||
Dual channel alarm output | Programmable alarm for high/low flow rate, air traffic control, fault status, positive/negative flow rate, analog over range, pulse over range, pulse small signal cutoff, with optional output polarity; Transistor switch output with isolation protection, capable of absorbing 250mA current and withstanding 35V voltage (Not isolated from pulse output) | ||||
digital communication | RS232,RS485,HART | ||||