The T968Y electric high-pressure differential regulating valve consists of a PS series or 3610 series linear electric actuator and a low flow resistance straight through single seat valve. (It can also be paired with other brands of direct travel actuators). The electric actuator is an electronic integrated structure with a servo amplifier inside. By inputting control signals (4-20mADC or 1-5VDC) and power supply, the valve opening can be controlled to adjust working parameters such as pressure, flow rate, liquid level, and temperature. It has the characteristics of sensitive action, simple connection, large flow rate, small volume, and high adjustment accuracy. The control accuracy and performance are significantly improved compared to the DKZ type.
Single seat valves are suitable for situations with strict requirements for leakage, low pressure difference before and after the valve, and a certain viscosity. Widely used in industries such as power, metallurgy, chemical, petroleum, environmental protection, light industry, equipment, etc.
Main technical parameters:
Nominal diameter mm | G3/4” | 20 | 25 | 32 | 40 | 50 | 65 | 80 | 100 | 125 | 150 | 200 | 250 | 300 | 350 | 400 | |||||||||
Valve seat diameter mm | 3 | 4 | 5 | 6 | 7 | 8 | 10 | 12 | 15 | 20 | 26 | 32 | 40 | 50 | 66 | 80 | 100 | 125 | 150 | 200 | 250 | 300 | Can collaborate with our company Negotiate production |
||
Rated flow coefficient kv | Linear type | 0.08 | 0.12 | 0.20 | 0.32 | 0.5 | 0.8 | 1.8 | 2.8 | 4.4 | 6.9 | 11 | 17.6 | 27.5 | 44 | 69 | 110 | 176 | 275 | 440 | 690 | 1000 | 1600 | ||
Equal percentage | 1.6 | 2.5 | 4 | 6.3 | 10 | 16 | 25 | 40 | 63 | 100 | 160 | 250 | 400 | 630 | 900 | 1440 | |||||||||
Nominal pressure (MPa) | 0.6,1.6,2.5,4.0,6.4 | ||||||||||||||||||||||||
Travel distance (mm) | 10 | 16 | 25 | 40 | 60 | 100 | |||||||||||||||||||
Traffic characteristics | straight line | Straight line, equal percentage, quick open | |||||||||||||||||||||||
Working temperature ℃ | -40-230 ℃ (normal temperature type), heat sink 230-450 ℃ (medium temperature type), special order -100-600 ℃ | ||||||||||||||||||||||||
Flange size | Compliant with JB78-59 and JB79-59 standards, can be ordered and produced according to JB/79.1-94, JB, ANSI, JIS, DIN and other standards | ||||||||||||||||||||||||
body material | WCB(ZG230-450)、ZG1Cr18Ni9Ti、ZG0Cr18Ni12Mo2Ti CF8 CF8M | ||||||||||||||||||||||||
Valve core material | 1Cr18Ni9,SS304,0Cr18Ni12Mo2Ti,SS316,ZG1Cr18Ni9Ti | ||||||||||||||||||||||||
Valve type | Straight through single seat cast ball valve | ||||||||||||||||||||||||
Upper valve cover type | Ordinary (room temperature), hot plate (medium temperature), long neck (low temperature) | ||||||||||||||||||||||||
Equipped with electric actuator model | PSL | PSL-201 | PSL-202 | PSL-204 | PSL-208 | PSL-312 | PSL325 | ||||||||||||||||||
361L | 361LSA-08 361LXA-08 |
361LSA-20 | 361LSB-30 | 361LSB- 50 |
361LSC-65 | 361LSC-99 | |||||||||||||||||||
Explosion proof type | 361LXA-20 | 361LXB-30 | 361LXB- 50 |
Note:
1. We can provide users with products that meet national flange standards such as ANSI, JPI, and JPI, with flange spacing determined according to user needs.
2. Products with working temperature, nominal pressure, and nominal diameter exceeding the listed range can be resolved through negotiation with our company
Main technical parameters of the executing agency:
model | Rated output force N | Speed mm/s | Technical Parameter | ||||
PSL | 361L | PSL | 361L | PSL | 361L | PSL | 361L |
201 | 361LSA-08 361LXA-08 |
1000 | 800 800 |
0.25 | 4.2 4.2 |
Power supply: AC220V 50Hz Input signal: DC4-20mA DC1-5V (Shielded wire for signal line) Output signal: DC4-20mA Protection level: IP67 With handwheel |
Power supply: AC220V 50Hz Input signal: DC4-20mA DC1-5V (Shielded wire for signal line) Output signal: DC4-20mA Protection level: equivalent to IP55 Explosion proof mark: Exd Ⅱ BT4 With handle |
202 | 361LSA-20 361LXA-20 |
2000 | 2000 2000 |
0.50 | 2.1 2.1 |
||
204 | 361LSB-30 361LXB-30 |
4500 | 3000 3000 |
0.50 | 3.5 3.5 |
||
208 | 361LSB-50 361LXB-50 |
8000 | 5000 5000 |
1.00 | 1.7 1.7 |
||
312 | 361LSC-65 | 12000 | 6500 | 0.60 | 2.8 | ||
325 | 361LSC-99 | 25000 | 10000 | 1.0 | 2.0 |
Performance indicators:
project | Indicator value | ||
Basic error% | Equipped with 3610L ± 2.5; Equipped with locator ± 1.0 | ||
Return difference% | Equipped with 361L ± 2.0; Equipped with PSL ± 1.0 | ||
Dead zone% | 1.0 | ||
Constant point deviation% | teletransmission | Starting point | ±2.5 |
End | ±2.5 | ||
Electricity off | Starting point | ±2.5 | |
End | ±2.5 | ||
Adjustable range | 50:1 | ||
Rated travel deviation% | 2.5 | ||
Discharge rate L/H | Compliant with JB/T7387-94 Level IV rated capacity of less than valve × 10-4 |
Allowable pressure difference:
Nominal diameter (mm) | 20 | 25 | 40 | 50 | 65 | 80 | 100 | 150 | 200 | 250 | 300 | ||||||
Valve seat diameter (mm) | 10 | 12 | 15 | 20 | 25 | 32 | 40 | 50 | 65 | 80 | 100 | 125 | 150 | 200 | 250 | 300 | |
actuator | Allowable pressure difference △ P (MPa) | ||||||||||||||||
Equipped with PSL | PSL202 | 6.4 | 6.4 | 6.4 | 4.90 | 3.14 | 1.92 | 1.23 | 0.78 | ||||||||
PSL204 | 4.31 | 2.76 | 1.76 | 1.04 | 0.69 | 0.44 | |||||||||||
PSL208 | 1.86 | 1.23 | 0.78 | 0.50 | 0.35 | 0.20 | |||||||||||
PSL320 | 1.26 | 0.87 | 0.49 | 0.32 | 0.22 | ||||||||||||
Equipped with 361L | 361LSA-20 | 6.4 | 6.4 | 6.4 | 4.90 | 3.14 | 1.92 | 1.23 | 0.78 | ||||||||
361LSB-50 | 4.79 | 3.06 | 1.96 | 1.16 | 0.76 | 0.49 | |||||||||||
361LSC-65 | 1.51 | 0.99 | 0.64 | 0.41 | 0.28 | ||||||||||||
361LSC-99 | 0.63 | 0.44 | 0.25 | 0.16 | 0.11 |