Portable oil content detector TD-500D
customer:
Project Manager: Manager Yuan+086 15910212151
Beijing Bolun Jingwei Technology Development Co., Ltd
Testing instruments:TD-500DPortable water oil analyzer
Detection principle: Fluorescence method (UV fluorescence method)
Instrument manufacturer: Turner, USA(Turner Designs)Hydrocarbon Instrument Co., Ltd
Application: Emergency response to oil pollution, on-site detection of pollution control
1、 Application situation
Application requirements: The State Environmental Protection Administration has included monitoring of petroleum in water as one of the six mandatory water quality indicators. The Discharge of Water Pollutants
Technical specifications for total monitoringHJ/T 92—2002》According to regulations, the polluting units of petroleum as a mandatory test item include the smelting industry, thermal power generation, coking, petroleum extraction, and petroleum refining30An industry or field.
Solution: Turner, USATD-500DPortable water oil analyzer
Specific applications: Emergency response to oil pollution, on-site detection of pollution control
2、 Regulatory standards
The detection and analysis methods for petroleum pollutants include infrared method, gravimetric method, gas chromatography method, and fluorescence method.
The infrared method is gradually being phased out due to the high toxicity of the solvents used, such as fluorocarbons and carbon tetrachloride, to the human body and their serious environmental pollution. According to the regulations issued by the United States Environmental Protection AgencyEPA Method 1664Method definition: Petroleum is extracted from n-hexane.
At present, ultraviolet fluorescence method has been widely used in developed regions and countries such as the United States, Canada, Switzerland, and Russia, and has been listed as a national standard. China's national standard "Marine Monitoring Specification"GB17378.3-1998Fluorescence method is also used to measure petroleum in seawater. China's water conservancy department is also considering using fluorescence method to measure oil pollution in surface water.
According to the Technical Specification for Monitoring Total Discharge of Water PollutantsHJ/T 92—2002》According to regulations, petroleum related polluting enterprises are mandatory testing items, including:
Metal mining, smelting industry, thermal power generation, coking, petroleum extraction, petroleum refining, chemical fiber, rubber products and natural rubber processing, pharmaceuticals, dyes, paints, synthetic detergents, synthetic fatty acids, other organic chemicals, machinery manufacturing, food, sugar industry, slaughtering and meat processing, beverage production, weapon industry, shipbuilding industry, alcohol and fermentation brewing industry, pipeline transportation industry, domestic sewage, hospital sewage, urban comprehensive sewage.
(1)Implementation standard for water quality: Comprehensive Wastewater Discharge StandardGB 8978-1996》
Permissible emission concentration of petroleum pollutants in the second category(mg/L) First level standard Secondary standard Level 3 standard
1997year12 month31All polluting units constructed recently 10 10 30
1998 year1 month1 All polluting units to be constructed in the future 5 10 20
(2)The Emission Standards for Water Pollutants in the Petroleum Refining IndustryGB3551-83》
Emission Standards for Water Pollutants in Petrochemical IndustryGB428119-1984(GB4281-84)》
project level Second level
Class I Class II Class III Class I Class II Class III
Petroleum category(mg/L) 5 5 10 10 10 20
(3)The Emission Standards for Water Pollutants in the Iron and Steel IndustryGB123456-1992》
Allowable emission concentration of petroleum: (unit)mg/L) First level standard Secondary standard Level 3 standard
1989.1.1Pre established and completed steel joint ventures 15 20 30
1989.1.1~1992.6.30Steel joint venture established and put into operation 10 10 30
1992.7.1Coking and steel joint ventures that were previously established and put into operation 8 10 30
since2009 year1 month1 From now on, there are existing joint ventures, steelmaking, and steel rolling
(Emission Standards for Water Pollutants in the Steel Industry)(200□ Draft for soliciting opinions) 5 (General exhaust outlet)
Portable oil analyzer (handheld oil concentration meter) from the United Statesmodel:TD500D
D-500D Oil In Water and Oil In Soil AnalyzerIt is a user-friendly, easy to operate, highly repeatable handheld portable instrument for analyzing and determining oil content in water and soil.
Application scope:
TD-500DPortable oil concentration in water/The soil oil concentration analyzer adopts fluorescence photometric detection technology and can use almost all conventional solvents as extractants to replace carbon tetrachloride, which is harmful to human health and pollutes the environment. This product is a handheld design, with the advantages of small size, light weight, high precision, rapid detection, etc. It is widely used in surface water, environmental monitoring, petroleum and petrochemical, hydrology and water conservancy, thermal power plants, steel manufacturing and other industrial sewage, wastewater, condensate, circulating water detection, marine oil spill, pipeline oil leakage and soil oil content determination.
Product features:
■Adopting advanced ultraviolet fluorescence spectrophotometry detection technology;
■High degree and high repeatability, with excellent correlation with infrared method;
■The dual channel dual range detection technology reduces errors caused by operation and greatly improves the concentration detection range. High concentration measurements do not require dilution of water samples;
■Dual channel dual range detection technology: measurement channel“A”Used for the detection of low concentration oils and refined hydrocarbon oils. range“B”Can detect water samples containing high concentrations of oil such as crude oil and lubricating oil(>1000mg/L)Without the need for dilution;
■Quick analysis methods. Less analysis steps, faster3Complete the testing of a sample in minutes;
■Excellent solvent compatibility, suitable for most conventional extraction solvents, and new research techniques can also be used:“Determination method without solvent”To detect;
■Easy calibration,CheckPOINTThe calibrator can provide fast and repeated calibration for field operations without the need for repeated calibration with standard solutions;
■Detect without interference from polar substances such as methanol;
■Disposable measuring tubes to avoid repeated contamination and interference between samples.
Technical parameters:
■Detector: Fluorescence detector
■Detection limit:
rangeA:<0.005mg/L;(Select)rangeB:<0.1 mg/L(Selected)
■Measurement range:
rangeA:0.005≤50mg/L; RangeB:>1000mg/L
■Degree:≤3%
■Reproducibility:≤3%
■Environmental temperature:0℃~45℃
■Relative humidity: Requirement <90%
■CECertification, protection level:IP67Waterproof and dustproof
■Handheld portable host, weighing only405gram
■Display:LCDdisplay
■External dimensions:4.45cm×8.90cm×18.40cm
■Automatic shutdown:3Automatic shutdown without touching the button for minutes
■Alarm function: low battery alarm and circuit fault alarm
■Preheating time:5second
■Power supply: Only required4sectionAAADry battery, measurable after each battery replacement1000More than once
■Equipped with a portable detection box, it is easy to operate on-site in the field
■Manufacturers useISO 9001/2000authentication.
TD-500D No-Solvent Oil-in-Water Analysis Method
Innovative oil detection and analysis method in water without the need for extraction solvents
The American company is a world leading expert in oil analysis instruments in water. The company has developed a complete set of analysis solutions for oil water quality, including online oil quality detectors, laboratory desktop oil meters, and portable handheld oil concentration analyzers. Widely serving departments such as petroleum and petrochemicals, offshore drilling platforms, industrial enterprises, and environmental monitoring, we help customers improve their oil water quality testing technology with excellent product performance.
A revolutionary method for detecting and analyzing oil concentration in water without the need for extraction solvents has been developed using innovative technology (requiring the purchase of an additional analysis kit).
The significant advantage of this method is that it can eliminate the harm to our own health and environmental safety caused by the transportation, use, and discharge of large amounts of extraction solvents in traditional water oil analysis processes. And under this reliable analysis method, it can effectively avoid measurement errors caused by personnel operations and the need to measure liquid water samples.
This detection method is completely dependent onTD-500DDesigned for portable water oil analyzer, it uses special oil surfactants in water to replace traditional extraction solvents, thereby achieving a new level of accuracy and reproducibility in detection results.
Characteristic description:
The instrument can measure all mineral oils, including heavy crude oil and light diesel oil dispersed in water.
Measurement range from low to<1mg/LUp to high10000mg/LThe measurement does not require dilution of the water sample, making it convenient for rapid operation in the field.
Detecting oil water quality without interference from soluble organic compounds in the water
Detecting oil water quality is not affected by the salinity and hardness of the water sample
Detecting oil water quality without interference from suspended solids in the water
The detection of oil water quality is not affected by changes in sample temperature during the operation process
The detection of oil water quality is not affected by the time difference between collecting and analyzing water samples
This detection method eliminates the requirement of collecting water sample volume
Water sample does not require acidification
No need for extraction reagents
Easy to operate, the entire analysis process can be completed in just a few minutes
1: The market price of this product in Chinese Mainland is 128000 yuan.
Water oil analyzer, oil-water analyzer, water quality oil analyzer, oil-water analyzer, handheld water oil analyzer, portable water oil analyzer, portable rapid oil analyzer, handheld rapid oil analyzer, dual channel portable water oil analyzer,TD500 dual channel water oil analyzer, solvent-free water oil analyzer, Turner Designs, Turner, USA, TD-500D
Partial user list:
China Ministry of Transport Environmental Protection Center |
TD-500D |
2 units |
Qingdao Huahai Group |
TD-500D |
3 units |
Jiangsu Maritime Safety Administration |
TD-500D |
3 units |
Sinopec Shengli Oilfield |
TD-500D |
1 unit |
Jilin Petrochemical Anjieshi (Changchun) Technology Co., Ltd |
TD-500D |
1 unit |
Dalian Aquaculture Research Institute |
TD-500D |
1 unit |
Qingdao Municipal Bureau of Ocean and Fisheries |
TD-500D |
1 unit |
Sinopec Environmental Research Institute |
TD-500D |
6 units |
Beijing Special Inspection Institute |
TD-500D |
1 unit |
Jilin Petrochemical |
TD-500D |
1 unit |
Environmental Testing Center of Guangzhou Ocean and Fisheries Bureau |
TD-500D |
1 unit |
Guangdong Provincial Hydrological Bureau Water Quality Monitoring Center |
TD-500D |
1 unit |
Huizhou Daya Bay Monitoring Center |
TD-500D |
1 unit |
Foshan Chancheng District Environmental Protection Bureau |
TD-500D |
1 unit |
National Marine Technology Center |
TD-500D |
2 units |
Hebei Maritime Safety Administration |
TD-500D |
2 units |
Xiamen Maritime Safety Administration |
TD-500D |
1 unit |
Guangdong Provincial Bureau of Marine Industry and Fisheries |
TD-500D |
13 units |
Jiangsu Maritime Safety Administration |
TD-500D |
1 unit |
Sinopec Northwest Oilfield |
TD-500D |
1 unit |
Baotou Iron and Steel Group |
TD-500D |
1 unit |
Sinopec Changling Refinery |
TD-500D |
1 unit |
Kunming Iron and Steel Plant |
TD-500D |
1 unit |
China Petroleum Exploration Science Research Institute |
TD-500D |
3 units |
Henan Oilfield |
TD-500D |
1 unit |
TD-500D Technical Service Solution
buyer:
Seller: Beijing Bolun Jingwei Technology Development Co., Ltd
1Installation acceptance
After receiving the installation notice from the buyer upon arrival of the instrument, the seller will arrange for a professional engineer to arrive at the buyer's site. The unpacking of the equipment will be carried out jointly by personnel from both parties. The seller's engineer will install, debug, provide technical guidance, and train the operator until they can operate independently. The installation tools will be provided by the seller.
Training includes1: Simple structure and functional description of the instrument (provide Chinese manual and operation manual)
2: Sample processing and equipment maintenance
3: Operation and general troubleshooting methods for instruments and equipment.
2: Warranty and after-sales service terms
1:TD-500DThe portable water oil content detector and accessories are covered by warranty for material and process defects during normal use, with a warranty period of one year from the date of installation. Users must comply withThe TD-500D user manual and the accompanying operation guide provide instructions for installing and starting the instrument and accessories.
The warranty does not include the following items:
1. Damage caused by contact with solvents, other corrosive liquids, and gases.
2. Damage caused by modifications made to the instrument.
3. Damage caused by improper operation and damage to the appearance of the instrument.
Provide technical support, supply parts at cost price outside the warranty period, and provide lifelong maintenance.