Jiangsu Guochuang Analytical Instrument Co., Ltd
Home>Products>TNS-3000 Intelligent Integrated Sulfur and Nitrogen Analyzer
TNS-3000 Intelligent Integrated Sulfur and Nitrogen Analyzer
Brief description: The intelligent integrated sulfur and nitrogen analyzer is a relatively advanced sulfur and nitrogen integrated analysis instrument
Product details

Intelligent integrated sulfur and nitrogen analyzersystem composition

1Intelligent integrated sulfur and nitrogen analyzerBasic system

·TNS-3000 Cracking Furnace

·TNS-3000S sulfur detection system

·TNS-3000N nitrogen detection system

·Computers and printers

·Liquid sampler

·Membrane dryer

·Photomultiplier tube

·Ozone generator

·Quartz tube

1.2 Other optional items

·Gas sampler

·Solid state sampler

IIBasic parameters

2.1 Power requirements

AC voltage: 220V ± 22V

Frequency: 50Hz ± 0.5Hz

Power: 2000 W

Power supply current: greater than 15A

Having a good grounding wire with a resistance to ground not exceeding 3 Ω

2.2 Air source requirements

Oxygen: Partial pressure 0.2 MPa (partial pressure), purity 99.99%, flow rate 400-650mL/min

Argon gas: partial pressure 0.2 MPa (partial pressure), purity 99.995%, flow rate 50-200 mL/min

Note: The water content of the gas used must be less than 5ppm!

2.3 Temperature control requirements and accuracy

Temperature control range: Room temperature~1050 ℃

Temperature control accuracy: ± 3 ℃

IIIIntelligent integrated analyzerEnvironmental requirements

3.1 Environmental temperature and lighting requirements

Maintain room temperature between 10 ℃ and 30 ℃, and keep it relatively stable. The instrument should avoid direct sunlight.

Attention: To ensure the normal and stable operation of the analysis system, it is recommended to use an air-conditioned room.

3.2 Requirements for dust and corrosive gases

The instrument should be kept away from places with dust and corrosive gases. Because corrosive gases can cause a decrease in electrical performance and affect the normal operation of refrigerators. Dust can affect the operation of the fan, causing an increase in temperature outside the cracking furnace and affecting the stability of the instrument; At the same time, dust can also adhere to the surface of the reaction chamber, leading to a decrease in luminescence intensity and affecting the sensitivity of the instrument.

3.3 Indoor space requirements

The indoor workbench must be kept stable and able to arrange the entire set of instruments in order to withstand their weight.

3.4 Ventilation and flammability requirements

Indoor air circulation must be maintained, and the presence of any flammable gases is strictly prohibited.

Attention: The temperature inside the high-temperature cracking furnace can reach 1050 ℃, and the presence of any flammable gas may cause an explosion!



Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!