Product details


TT260 Coating Thickness Gauge


☆ Measurement range: 0-10000


☆ Operating frequency: 0.01cm/s~19.99cm/s


☆ Detection accuracy: 0.1um


☆ Indication error: ± [3% H+1]








Product Introduction

----------------------------------------------------------------------

TT260 Coating Thickness GaugeIt is a portable measuring instrument that can quickly, non destructively, and accurately measure the thickness of coatings and plating layers. It can be used in both laboratories and engineering sites. By using different probes, various measurement needs can also be met. This instrument can be widely used in manufacturing, metal processing industry, chemical industry, commercial inspection and other testing fields. It is an essential instrument for material protection professionals. This instrument meets the following standards: GB/T 4956-1985 Measurement of thickness of non-magnetic coatings on magnetic metal substrates Magnetic methods GB/T 4957-1985 Measurement of thickness of non-conductive coatings on non-magnetic metal substrates Eddy current methods JB/T 8393-1996 Magnetic and eddy current coating thickness measuring instruments JJG 889-95 "Magnetic resistance thickness gauge" JJG 818-93 "Eddy current thickness gauge"

Functional features:

This instrument adopts two thickness measurement methods, magnetic and eddy current, which can non destructively measure the thickness of non-magnetic coatings (such as zinc, aluminum, chromium, copper, rubber, paint, etc.) on magnetic metal substrates (such as steel, iron, alloy, and hard magnetic steel) and non-conductive coatings (such as rubber, paint, plastic, anodized film, etc.) on non-magnetic metal substrates (such as copper, aluminum, zinc, tin, etc.).

Can use 7 types of probes (F400, F1, F1/90 ° F10、CN02、N1)

● It has two measurement methods: Continuous measurement method and Single measurement method;

● It has two working modes: Direct mode and Group mode (A-B)

There are five statistical measures: Mean, Maximum, Minimum, Number of Tests, and Standard Deviation;

Two methods can be used to calibrate the instrument, and the basic calibration method can be used to correct the system error of the measuring head;

● With storage function: capable of storing 495 measurement values;

● It has a deletion function: it can delete a single suspicious data that appears in the measurement, and also delete all data in the storage area for new measurement;

● Set limit: Automatic alarm for measurement values outside the limit; And a histogram can be used to analyze a batch of measurement values

● Printing function: capable of printing measurement values, statistical values, limits, and histograms;

● It has the function of communicating with a PC: it can transmit measurement values and statistical values to the PC for further processing of data;

● Equipped with power undervoltage indication function;

● There is a buzzing sound during the operation process to prompt;

● Equipped with error prompt function, providing error prompts through screen display or beeping sound;

There are two shutdown modes available: manual shutdown mode and automatic shutdown mode

Technical parameters:

overburden
matrix

Non magnetic coatings such as organic materials (such as paints, coatings, enamel, porcelain enamel, plastics, and anodizing treatments)

Non magnetic non-ferrous metal coating (such as chromium, zinc, aluminum, copper, tin, silver, etc.)

The thickness of the covering layer shall not exceed 100 μ m

The thickness of the covering layer exceeds 100 μ m

The thickness of the covering layer shall not exceed 100 μ m

The thickness of the covering layer exceeds 100 μ m

Like iron and steel
Equal magnetic metal

The diameter of the measured area is greater than 30mm

F400 probe 0-400 μ m
F1 type probe 0-1250 μ m

F1 type probe 0-1250 μ m
F10 type probe 0-10mm

F400 probe 0-400 μ m
F1 type probe 0-1250 μ m

F1 type probe 0-1250 μ m
F10 type probe 0-10mm

The diameter of the measured area is less than 30mm

F400 probe 0-400 μ m

F400 probe 0-400 μ m
F1 type probe 0-1250 μ m

F400 probe 0-400 μ m

F400 probe 0-400 μ m
F1 type probe 0-1250 μ m

Such as copper, aluminum
Brass, zinc, tin
Waiting for non-ferrous metals

The diameter of the measured area is greater than 5mm

N1 type probe 0-1250 μ m

Only used for N1 type probe with chrome plating on copper 0-40 μ m

Plastic, printed circuit non-metallic substrate

The diameter of the measured area is greater than 7mm

-

-

CN02 probe 10-200 μ m

Probe type

Optional, see attached table

measuring principle

Magnetic induction and eddy current

measuring range

Probe decision

Low resolution limit

Probe decision

Probe connection method

Split type wire connection (replaceable)

Indication error

A little calibration (um)

Probe decision

Two point calibration (um)

Probe decision

Measurement conditions

Minimum curvature radius (mm)

Probe decision

Diameter of the minimum area of the substrate (mm)

Probe decision

Minimum critical thickness (mm)

Probe decision

Temperature and humidity

0~40℃
20%RH~90%RH

Statistical function

Mean, Max, Min
Test frequency (NO.), standard deviation (S.DEV)

operation mode

Direct method and group method (Appl)

Measurement method

Continuous measurement method and Single measurement method

Upper and lower limit settings

have

Storage capacity

495 measurement values

Print/Connect Computer

Comes with a printer/can connect to a computer

Shutdown mode

Manual and automatic

Power Supply

1/2 nickel hydrogen battery 5 × 1.2V

External dimensions

270×86×47mm

weight

530g

TT260 Coating Thickness Gauge Optional Probe Parameter Table

Probe model

F400

F1

F1/90

F10

N1

CN02

working principle

magnetic induction

Eddy current

Measurement range (um)

0-400

0-1250

0-10000

0-1250 (chrome plating on copper 0-40um)

10-200

Low resolution (um)

0.1

0.1

10

0.1

1

Indication error

A little calibration (um)

±[3%H+1]

±[3%H+10]

±[3%H+1.5]

±[3%H+1]

Two point calibration (um)

±[(1~3)%H+0.7]

±[(1~3)%H+1]

±[(1~3)%H+10]

±[(1~3)%H+1.5]

-

Measurement conditions

Minimum curvature radius (mm)

Convex 1

Convex 1.5

Flat and straight

10

3

Flat and straight

Diameter of the minimum area of the substrate (mm)

ф3

ф7

ф7

ф40

ф5

ф7

Minimum critical thickness (mm)

0.2

0.5

0.5

2

0.3

unlimited

Basic configuration:

HostPrinter, F-head or N-head, standard sheet set (50um, 100um, 200um, 500um, 1000um), iron or aluminum substrate, charger

Optional attachments:

Probe (F400, F1, F1/90 ° F10、CN02、N1)、 Communication cables, communication software