TT260Q Coating Thickness Gauge


☆ Measurement range: 0~1500 μ m


☆ Operating frequency: 1


☆ Detection accuracy: ± (2%+1)


☆ Indication error: 0.1 μ m








Product Introduction

----------------------------------------------------------------------

TT260QThe portable coating thickness gauge can quickly, non destructively, and accurately measure the thickness of coatings and plating layers. This instrument can be widely used in testing fields such as electroplating, anti-corrosion, aerospace, chemical, automotive, shipbuilding, light industry, and commercial inspection. Configure different probes for different occasions.TT260QThe coating thickness gauge adopts two thickness measurement methods: magnetic method and eddy current method. Capable of measuring magnetic metal substrates(Such as steel, iron, alloys, and hard magnetic steel, etc)Thickness of non-magnetic coating on top(Such as zinc, aluminum, chromium, copper, rubber, paint, etc)It can also measure non ferromagnetic metal substrates(Such as copper, aluminum, zinc, tin, etc)Thickness of non-conductive coating on austenitic stainless steel(as:Rubber, paint, plastic, anodized film, etc).

main features
Ø(2%+1)/(1%+1) High measurement accuracy
ØShort measurement response time and fast measurement speed
ØSplit design, strong applicability and stable measurement values
ØPowerful data processing and analysis: 5 statistical values and histograms
Ø7 types of probes (F400, F1, F1/90 °, F10, N400, N1, CN02) are available for selection to meet customers' various measurement needs


performance index
measuring range 0~1500μm
measurement accuracy One point calibration: ± (2%+1) Two point calibration: ± (1%+1)
calibration method One point calibration/Two point calibration/Basic calibration
Display resolution 0.1 μ m (measurement range less than 100 μ m) 1 μ m (measurement range greater than 100 μ m)
weight 250g (including battery pack)
work environment Temperature: 0 ℃~50 ℃ Humidity: 20%~90%
operation mode Direct and group methods
Measurement method Continuous measurement/single measurement
Shutdown mode Manual shutdown/automatic shutdown
Operation tips Music ringtone, error message
signal processing
Threshold limit Automatic alarm for measurement values outside the limit
Data analysis A histogram can be used to analyze a batch of measurement values
statistic Mean (MEAN)/Standard Deviation (S.DEV)/Number of Tests (No.)/Maximum Test Value (MAX)/Minimum Test Value (MIN)
storage
Thickness value 500 pieces of data
delete Single suspicious data/all data within the group
Power Supply
Battery Commercial nickel hydrogen/alkaline battery 9V
Power monitoring Under voltage indication
Standard configuration 1 host
1 probe (N1 or F1)
4 standard pieces
1 piece of substrate
1 9V alkaline battery
1 user manual
Optional selection
printer Serial port thermal printing

Probe model F400 F1 F1/90° F10 N400 N1 CN02
working principle Magnetic induction Eddy current
Measurement range (mm) 0~400 0~1250 0~10000 0~400 0~1250 10~200
(Copper plated with chrome 0-40)
Low resolution (mm) 0.1 0.1 10 0.1 0.1 1
Indication value
error
One point calibration (mm) ±(3%H+0.7) ±(3%H+1) ±(3%H+10) ±(3%H+0.7) ±(3%H+1.5) ±(3%H+1)
Two point calibration (mm) ±(1%H+0.7) ±((1%H+1) ±(1%H+10) ±(1%H+0.7) ±(1%H+1.5) --------
test
condition
Minimum curvature radius (mm) Convex 1 1.5 Flat and straight 10 Convex 1.5 3 Flat and straight Just straight
Minimum area diameter (mm) F3 F7 F7 F4 F4 F5 F5 F7
Critical thickness of substrate (mm) 0.2 0.5 0.5 2 0.3 0.3 0.3 unlimited
Reference Table for Probe Selection (1)
overburden
matrix
Organic materials and other non-metallic coatings (such as paints, coatings, enamel, porcelain enamel, plastics, and anodizing treatments)
The thickness of the covering layer shall not exceed 100mm The thickness of the covering layer exceeds 100mm
Magnetic metals such as iron and steel The diameter of the measured area is greater than 30mm F400 probe 0-400mm
F1 type probe 0-1250mm
F400 probe 0-400mm
F1 type probe 0-1250mm
F10 type probe 0-10mm
The diameter of the measured area is less than 30mm F400 probe 0-400mm F1 type probe 0-1250mm
F400 probe 0-400mm
Nonferrous metals such as copper, aluminum, brass, zinc, tin, etc The diameter of the measured area is greater than 10mm N400 probe 0-400mm
N1 type probe 0-1250mm
N400 probe 0-400mm
N1 type probe 0-10mm
The diameter of the measured area is less than 10mm N400 probe 0-400mm N1 type probe 0-1250mm
N400 probe 0-400mm
Reference Table for Probe Selection (2)
overburden
Matrix
Non magnetic non-ferrous metal coating (such as chromium, zinc, aluminum, copper, tin, silver, etc.)
The thickness of the covering layer shall not exceed 100mm The thickness of the covering layer exceeds 100mm
Magnetic metals such as iron and steel The diameter of the measured area is greater than 30mm F400 probe 0-400mm
F1 type probe 0-1250mm
F400 probe 0-400mm
F1 type probe 0-1250mm
F10 type probe 0-10mm
The diameter of the measured area is less than 30mm F400 probe 0-400mm F400 probe 0-400µm
F1 type probe 0-1250mm
Nonferrous metals such as copper, aluminum, brass, zinc, tin, etc The diameter of the measured area is greater than 10mm Only used for chrome plating on copper
N400 probe 0-40mm
--------
The diameter of the measured area is less than 10mm -------- --------
Plastic, printed circuit non-metallic substrate The diameter of the measured area is greater than 7mm CN02 probe 10-200mm CN02 probe 10-200mm
Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!