TY-CL8Pesticide residue rapid testing instrument
This instrument is mainly used for detecting the residual toxicity content of organic phosphorus and carbamate pesticides in vegetables, fruits, tea, etc., and is particularly suitable for rapid testing before harvesting in agricultural bases and professional households; On site speed testing of agricultural wholesale markets and vegetable distribution centers; Supermarkets, canteens, and other pre processing speed tests. This instrument is also used by agricultural product pollution-free quality supervision and testing centers, industrial and commercial departments, health and epidemic prevention stations and other institutions to detect and control pesticide residues in vegetables and fruits.
1、 Equipment configuration parameter description
1.According to the standard: According to the national standardGB/T5009.199-2003;
★2.colorLCD 5inch800*400Dot matrix large screen Chinese touch screen display, which can display various data, measurement results, and other information in real-time during the measurement process Operation prompt information to achieve good human-machine dialogue function;
★3.Unique enzyme reagent activity determination function, automatically determines whether the reagent is effective, and automatically alarms if it fails;
★4.Microcomputer communication interface with upper computer software, capable of both computer control and independent instrument operation; Realize seamless connection of data network;
5.Large capacity storage, capable of storing over 35000 pieces of data, and able to query any set of raw data stored based on time or sequence number;
6.Equipped with an embedded thermal printer, the detection results can be quickly and automatically printed, and the printed results can display the full name of the unit and the name of the inspector;
7.Original imported long-life non thermal solid-state light source, high precision, stable performance, controllable light source, greatly extending service life;
★8.Intelligent judgment of whether there is a sample in the channel, and the detection result will be available within three minutes;
9.Array style cassette design,8An independent automatic detection bracket, easy to operate, capable of simultaneous testing8A sample;
10.Please input the testing unit, testing time, testing personnel, and names of the testing samples by yourself.
2、 Technical parameters:
1Light source wavelength: 410 ± 2nm
2Wavelength repeatability: ± 1.5 nm
3Transmittance accuracy: ± 0.3% T
4Transmittance indication error (%): 0.3
5Transmission specific gravity repeatability: ± 0.5% T
6Inhibition rate measurement range: 0-100%
7Pesticide detection line: 0.1-5mg/kg
8Wavelength accuracy: ± 2nm
9. ● Metering method: T%(%T)、A、T%
10. ● Luminous range: 0% T to 200% T(
11. ● Operating environment: Temperature:
12Power supply voltage: AC 200~240V, 50Hz
Technical parameters of pesticide residue analyzer (TY-CL8 type)
1Light source wavelength: 410 ± 2nm
2Wavelength repeatability: ± 1.5 nm
3Transmittance accuracy: ± 0.3% T
4Transmittance indication error (%): 0.3
5Transmission specific gravity repeatability: ± 0.5% T
6Inhibition rate measurement range: 0-100%
7Pesticide detection line: 0.1-5mg/kg
8Wavelength accuracy: ± 2nm
9. ● Metering method: T%(%T)、A、T%
10. ● Luminous range: 0% T to 200% T(
11. ● Operating environment: Temperature:
12Power supply voltage: AC 200~240V, 50Hz

Standard configuration list:
Serial Number |
name |
specifications |
quantity |
1 |
host (Built in thermal printer) |
TY-CL8 |
1tower |
2 |
power line |
|
1root |
3 |
balance |
500g,0.1g |
1individual |
4 |
glass rod |
|
1root |
5 |
fruit knife |
|
1individual |
6 |
tweezers |
|
1individual |
7 |
tube brush |
|
1individual |
8 |
plastic sheeting |
|
1individual |
9 |
Suction head |
|
6individual |
10 |
Bottle washing |
250mL |
1individual |
11 |
Plastic wide mouthed bottle |
500mL, with cover |
1individual |
12 |
Pipette |
50-250μL;1000-5000μL |
2branch |
13 |
glass tube |
10mL |
10individual |
14 |
test tube rack |
|
1individual |
15 |
centrifuge tube |
50mL, with cover |
8individual |
16 |
Colorimetric dish |
10mm |
8only |
17 |
Pesticide residues and biochemical agents |
|
1cover |
18 |
Instruction manual, certificate of conformity |
|
1cover |