TimmTZB/400.3NThe (intelligent) leakage protector is the latest product developed and researched by our company to improve the load switching performance of low-voltage power grid terminals. It integrates leakage protection, automatic reclosing mechanism for leakage faults, overload and short circuit protection, and has the characteristics of easy installation and reasonable structure. This product is suitable for low-voltage distribution systems with three-phase four wire neutral point directly grounded, used for ground fault protection of the line. To prevent equipment accidents or electrical fires caused by this, it can also be used to provide indirect contact protection against personal electric shock hazards. Widely applicable for overall protection of industrial and mining enterprises, distribution transformers, orderly use of electrical load control switches, and timely control switches. This product meets the standardsGB14048.2-2008andGB13955-2005The requirements for the installation and operation of residual current action protection devices have been approved by the national government3CCompulsory certification, this product is covered by quality liability insurance provided by Ping An Insurance Company of China.
1. It has the functions of short circuit, overload, undervoltage, overvoltage, phase loss, zero disconnection, and automatic reclosing. 2The leakage action value can be manually adjusted, or the leakage action value can be automatically adjusted by tracking the circuit leakage. 3The overload protection value can be adjusted according to the transformer capacity or actual load demand. 4Digital display of three-phase load current, power supply voltage value, and line leakage current value. 5After tripping, the tripping reason and fault current can be automatically displayed. 6It has automatic and manual closing functions, making it convenient for users to use. 7When the leakage alarm function is activated, only the leakage value is displayed, and if the leakage exceeds the limit, only the alarm will be triggered without tripping. 8Built in communication interface, capable of remote control, telemetry, and remote signaling functions. 9Can query the reasons and occurrence times of previous trips (optional) 10The function of distinguishing sudden wave currents (similar to sudden waveforms of animal electric shocks) can be set. (Optional) 1Rated current400A 2Rated voltage380V 3Rated insulation voltage400V 4Rated frequency50HZ 5Rated auxiliary power supply voltage220V 6Surge leakage action value ≤50 mA 7Rated residual operating current 100/150/200/300/500/800/1000mA(Adjustable) 8Rated residual non operating current ≥1/2I△n 9Remaining current interruption time ≤0.3 S、 ≤0.5 S(Adjustable) 10Minimum non driving time1I△n 0.13S、2I△n 0.06S、5I△n 0.05S 11、 Delay reclosing time20 - 60SRecloser once 12、 Action characteristic categoryACtype 13Classification of Separation TimeStype 14Rated short-circuit breaking capacity25KA 15Rated residual short-circuit making and breaking capacity6.25KA 17Adjustable range of load current 200~400AEach level20A 1.work environment 1.1ambient temperature: -40~ 60℃ 1.2relative humidity:≤90% 1.3altitude:≤2000rice 1.4pollution degree: 3level 1.5The protector should be installed in a dry, ventilated, dust-free, and free of harmful gases, away from magnetic fields and vibrations. It should be vertically fixed on the distribution box or wall for easy operation. 2.Usage 2.1 Power transmission Place the power switch of the protector in the 'ON' position, and the 'Close' indicator light will start flashing (indicating a waiting state for closing). The electric closing mechanism of the protector will operate. When the closing is in place, it will be in the normal closing state, and the 'Close' indicator light will remain on. 2.2 close electricity Set the power switch of the protector to the off position, trip the protector, and turn off the main circuit. 2.3Leakage over limit tripping test: Press the 'Leakage Test' button,protectorIt should be able to trip, the leakage indicator light is on, the closing indicator light is off, and it exceeds the limit5In seconds, the [Close] indicator light starts flashing (the electric closing mechanism is running and in a closed waiting state), indicating that the electric closing mechanism is in operation20~60The automatic closing is completed in seconds. After the closing is in place, the leakage indicator light goes out and the closing indicator light remains on. 2.4 Setting of leakage action value: Manual adjustment and automatic adjustment can be selected as needed According to the magnitude of the leakage current in the circuit, the leakage action value level of the protector can be manually set, or the leakage action value can be automatically set to levels I, II, and III; According to different specifications,The leakage current of each gear corresponds to: gear I:200mA Grade II:500mA Grade III:800mA. (Optional upon request) Press the 'Leakage Setting' button to set the gear, and continuously press the 'Leakage Setting' button to set the gearI gear → II gear → III gear → cyclic conversion; Press and hold【 Leakage setting 】 Enter automatic gear setting within 3 seconds.(When)The gear indicator light is always on for a certain gear, indicating a manually set fixed gear. When the gear indicator light flashes, it indicates an automatic gear. If the gear is fixed, the power protection device has a gear memory function when turned off and turned on after power failure, and the gear remains the same as the original gear; If the automatic gear is turned off and then turned on, or if there is a power outage, the power protection device will automatically set the gear based on the leakage of the power line. 2.5This protector cannot automatically close due to overload or short circuit tripping. The power switch of the leakage protector needs to be turned off and reconnected before power can be restored. 2.6 The auxiliary power supply used in the internal electronic circuit of this protector isNPile and1Pile, if used for three-phase power protection or specifically for single-phase protection,NThe pile must be connected to the neutral wire,1The pile must be connected to the phase line, otherwise it cannot be powered on or manually closed without leakage protection. 2.7Press and hold the 'Alarm Start' button when power outages are not allowed or when power must be supplied due to leakage faults at inspection stations5In seconds, the alarm function is activated, and the [Alarm] light is on. At this time, only the [Leakage] indicator light is on when the leakage exceeds the limit, without tripping. The use of this feature must be approved by the local power department. After entering the alarm state, press and hold the 'Alarm Start' button again5Restore the leakage tripping function in seconds. 2.8The opening and closing indicator block is used to indicate the opening and closing status of the protector. 2.9 When the leakage tripping does not require automatic reclosing function, or when the internal closing motor is damaged, manual closing can be used, and an Allen wrench can be used to press the orderTurn the device clockwise to the closed state and stop (when the indicator block is "closed"). If manual opening is required, turn the device clockwise again to the open state and stop. If manual closing is required again, the protector must be turned on[Power switch]Re open and close once, then turn the device clockwise until it is in the closed position and stop. 2.10 Digital display loop displayA□□□□B□□□□C□□□□A.□□□□B.□□□□C.□□□□L□□□□F□□□ Display as three-phase current values respectively(A)Three phase voltage value(V), and leakage current value(mA)TheLoad current control value(A)Press the [Function Selection] keynumerical codemonitorDisplay the following parameters in sequence: -AA-——Indicating leakage phase A E005——Indicating the cumulative number of trips5order H003——Indicating the cumulative number of tripping and locking events3order R=05——Indicate the interruption time0.5S d =01——Expressingmail addressset up 7b=0——Indicate surge protection settings 9H=0——Indicate the phase loss protection setting 2.11When the circuit breaker trips, the digital display will flash to show fault information aLeakage fault tripping Display fault current and tripping phase alternately, whileThe leakage indicator light is on, and the closing indicator light is off. Example: If L345 → - AA - is displayed, it indicates that this trip is a leakage trip, with a fault current of 345mA and A-phase leakage. If - Cd - is displayed, it indicates a surge leakage trip. bUnder overvoltage tripping Trip display -9Y - indicates undervoltage tripping, and the [closing] light is off at the same time. After the power supply voltage returns to normal, the circuit breaker automatically closes and supplies power. cLoad control tripping The digital display flashes and alternately displays the load current values of each phase before tripping, while the overcurrent indicator light is on. 2.12Trip record query:Press continuouslyThe [Function Selection] key allows for digital selectionmonitorDisplay as EXXX (XX is the number of trips), then press and hold the 【 Function Selection 】 key for 3 seconds to enter the digital displaymonitorDisplay as E=XX, press again【Leakage setting】Press the key to display the reason for the most recent trip. To view the next item, press the [Function Selection] key first and then press again【Leakage setting】Key; To exit, press and hold the 【 Function Selection 】 key for 3 seconds to activate the digital functionmonitorLXXX displays the status of all parameters normally. 2.13Breaking time setting:Press continuouslyThe [Function Selection] key allows for digital selectionmonitordisplay asR=05.Then press and hold the [Function Selection] key first, and then press【Leakage setting】Key SettingsR=03Change the interruption time to 0.3SFactory default is0.5S) 2.14mail address When the digital header displays d=01 (02, 03, 04), it means that the local communication address is 01 (02, 03, 04). At this time, press and hold the display selection key, and then press the leakage setting key to modify the communication address. 2.15Surge Protection When the digital meter displays Tb=0, it indicates that the surge protection is disabled, and Tb=1 indicates that the surge protection is enabled. At this time, first press and hold the display selection key, and then press the leakage setting key to modify whether to enable or disable it. 2.16Phase loss protection setting Press continuouslyThe [Function Selection] key allows for digital selectionmonitordisplay as9H=0.Then press and hold the [Function Selection] key first, and then press【Leakage setting】Key Settings9H=1,The phase loss function is activated. To cancel, repeat the above steps. 2.17Load control current regulation method Continuously pressing the 'Function Selection' button will display 'FXXX' on the monitor”At this time, "XXX" represents the negative control current value. First, press and hold the "Function Selection" button, then press the "Leakage Setting" button. Each time you press the "Leakage Setting" button, the load control value changes once until it reaches the desired value. Release both buttons and wait for a period of time before automatically confirming. |