The pyroelectric measurement system consists of a pyroelectric reader and an annealing furnace. The T360M manual pyroelectric reader is available in two versions: the standard version and the simplified version. It is a high-quality, reliable, and cost-effective pyroelectric and photoluminescence reader. It can effectively measure the radiation dose absorbed by the thermal and luminescent elements packaged in the dose box. Manual single-chip reading of dosage components. IDMS software integrates a result database, allowing operators to easily manage measurement data in various formats and generate measurement reports in specific formats.
Key features:
The device has the ability to measure and read both thermoluminescence and photoluminescence
The device can run independently (without the need to connect to a computer)
The system automatically deducts the natural background through calculation
The device can directly measure and read dose components
The IDMS software system integrates a database for easy data management
Free combination dosimeter box meets different measurement needs
10.4 'touch screen, convenient for user operation, operation and maintenance
RS232 and USB interface connection to computer
Contact electric heating, optional gas heating
Unique laser excitation technology for photoluminescence measurement
Intelligent integration capability, accurate acquisition of measurement data
Automatic injection and withdrawal technology of patented technology
CUT-Level patented technology effectively accelerates the measurement process
Various medium density filters effectively expand the measurement range
Photomultiplier tube semiconductor refrigeration and water refrigeration
The equipment has self diagnostic capability and remote diagnostic function
Multi language interface: Chinese, English, French, Spanish, German, Russian, Arabic, etc
Typical applications:
Verification of Radiation Therapy and Diagnostic Dose
Whole body and skin irradiation dose detection
Dose verification of crisis organs
CT dose verification in quality assurance
Environmental radiation dose detection
Testing of irradiated food
Archaeological and Geological Radiodating
Environmental conditions:
Municipal power supply: 110~250V, 50/60Hz Power less than 300 watts
Operating temperature: 0 ℃~50 ℃; Storage temperature:- 20℃~60℃
Dimensions: 470 * 340 * 300mm Unit weight: 25kg
The overall chassis is resistant to 1000 lux ambient light exposure
Time Temperature Trace (TTP)&Time Power Trace (TPP):
Heating temperature: 15 ℃ -300 ℃, maximum temperature: 400 ℃
Preheating temperature: 50~135 ℃ Obtain temperature: 200℃~300℃
Heating rate: 1℃/s ~ 50℃/s
Annealing temperature: 15 ℃ -400 ℃ Annealing time: 15 minutes
HV: 0~-1500V (software settings) High voltage stability: < 0.005%
Dose data reading system parameters:
Heating method (thermoluminescence): Unique heating module, passive heating
Refrigeration: semiconductor refrigeration+gas refrigeration
Linearization: ≤ 1% Heating temperature stability (control accuracy): ± 1 ℃
Dose linear measurement range: 10-9 Gy to 11 Gy (LiF: Mg, Cu, P) (with attenuation filter)
0-499Gy (LiF: Mg, Ti-M) (with attenuation filter) 0-1Gy (LiF: Mg, Ti)
Heating temperature deviation: ≤± 1 ℃; Heating time repeatability: ≤ 0.1%
Repeatability: 1mGy Cs137, deviation<1%
Testeable items: γ. Beta, X-ray dose, neutron
Stability: 10 consecutive measurements, SD ≤1μGy
Dark current: RSD ≤ 1% Reference light: ≤ 0.5% Continuous 10 readings
Dose measurement range: 0.01 μ Sv-50Sv (with medium density attenuation filter)
Reading ability: Single piece reading test
Reading time: Standard TTP, read one dose element in 40 seconds
Introduction to Annealing Furnace Parameters:
Dimensions: 300 * 225 * 160 millimeters
Whole machine weight: 3 kilograms
Packaging size: 450 * 450 * 300 millimeters
Packaging weight: 5 kilograms
Power supply requirements: AC mains power AC220V, 50HZ power 650W
Built in 6A fuse
Maximum temperature of heating unit: 0~800 ℃
Annealing unit temperature range: 0~500 ℃
Temperature overshoot value: 2 ℃ below the preset value
Control mode: microcomputer program control, five function key control
Cooling methods: air cooling, large-area metal plate cooling
Operation display: Electronic tube display, display accuracy of 0.3 level
Temperature measurement method: thermocouple contact temperature measurement, with a resolution of 0.1 ℃
Annealing temperature setting: manually set within 0~500 ℃
Annealing time setting: freely set within 100 minutes, with alarm
System software (database):
Settings for workstations or operational functions
Setting, obtaining, and storing measurement parameter parameters
Reader Calibration Factor (RCF)
Automatic background deduction
Original data and analysis curve analysis
Export tables and text files
Periodic diagnosis ensures that the equipment is in optimal working condition
The measurement result exceeds the threshold alarm function according to: date, time, point number, and detection result