Tuttnauer, Israel: Tuttnauer Laboratory High Pressure Steam Sterilizer TLC5075
FAQ Q: What does the machine display code "102" mean for desktop sterilizer products? A: Incorrect operation causes the machine to enter engineer mode
Product details
Desktop Sterilizer Product FAQ
Q: What does the machine display code "102" mean? A: Incorrect operation causes the machine to enter engineer mode, which can be exited by restarting or pressing the stop button. Q: May I ask if the "fail" indicator light of the sterilizer is on and the sterilization program cannot continue running? What should I do? A: When the 'fail' indicator light is on, please record the error code on the display screen, compare it with the instructions to find the cause and solution of the fault, or contact a Mason product engineer. Q: May I ask if the sterilizer can be manually refilled with water? A: Okay. Q: May I ask about the maintenance that should be performed on the sterilizer every day? A: The door gasket should be cleaned daily with harmless cleaning agents, water, and a soft cloth or sponge. The gasket should be kept clean and smooth. Q: May I ask about the maintenance that should be performed on the sterilizer every week? A: 1. The nozzle should be cleaned once a week. To ensure the normal temperature rise inside the sterilization chamber, it is necessary to keep the nozzle clean. The contaminated jet nozzle will hinder the discoloration of the sterilization indicator strip, leading to the failure of spore testing. Use a damp cloth or sponge to clean the water level sensor installed at the rear of the sterilization chamber. Cleaning the dirt on the side of the sensor is more important than cleaning the dirt on its top. Using Chamber Brite ™ Clean and descaling the sterilization chamber, copper tube, and water tank with solvent once a week. 4. Remove the tray rack and tray. Use a cleaning agent or non abrasive stainless steel cleaner and water, and clean the tray rack and tray with a cloth or sponge. Immediately rinse the tray rack and tray with water to avoid leaving stains on the metal. Drop a few drops of oil on the two door pins and door fastening bolts. Use a soft cloth to clean the external parts of the sterilizer. Q: May I ask about the regular maintenance of the sterilizer? A: Clean and inspect the safety valve once a month. For EA and EKA sterilizers, replace the air filter every six months or as needed. Replace the door gasket every twelve months or as needed. Every six months, compressed air should be used to blow the fan grille from the inside out. Clean the water filter once a month. The cleaning frequency can be reduced based on previous maintenance experience. Check the locking device once a year to see if there is excessive wear and tear. Q: May I ask if the sterilizer requires maintenance technicians to perform preventive and regular maintenance? A: No need, office personnel can easily follow and follow the operating instructions to maintain the equipment. Q: May I ask about the water quality requirements for this sterilizer? A: Supply distilled water to the sterilizer. Q: May I ask why there is no obvious steam emission and no hissing sound during the heating and sterilization process? A: Possible blockage of the steam nozzle, please clean the nozzle according to the instructions. |
Online inquiry