Puhui brand ultraviolet drinking water processor
UV drinking water processors are divided into two types: manual control and self-control, usually of the manual control type; The product shell material is SUS304 stainless steel plate. If the working pressure is higher than 0.6MPa, it can be customized without increasing the price. The working pressure is 1.0MPa or higher; The connection methods DC1-30, DB3-30, and DB4-30 are threaded connections, which are actually flange connections. The working conditions can be customized with connection methods; The 'existing model' refers to the model currently supplied by our company, and non-standard models need to be customized.
Water is one of the important conditions for maintaining life. The water content in the human body accounts for about 65% of body weight, and under normal circumstances, each person needs to consume 2-3 liters of water per day. Water is also a medium for various forms of communication. Cholera, typhoid fever, dysentery, leptospirosis, and infectious diseases can all be transmitted through water. Water is also susceptible to pollution from industrial wastewater, domestic wastewater, and human and animal feces, leading to the deterioration of water quality.
In order to prevent secondary pollution of water and promote human health, the "Sanitary Standards for Drinking Water" and the "Measures for the Supervision and Management of Sanitary Standards for Drinking Water" have been successively promulgated.
What I have developedUV drinking water processorIt is made using the biological effects of ultraviolet light with wavelengths between 2000 and 3000 angstroms (A). Effective and easy to operate, it is an ideal drinking water device.
We have developed and produced a self controlled ultraviolet drinking water processor equipped with a CK23 flow switch sensor device, which combines aerospace technology. It has the characteristics of energy saving and consumption reduction, and does not require personnel operation. As long as the water flow rate in the pipeline reaches 5 liters per minute, it will automatically start, making the water meet the drinking water standard, thus compensating for the disadvantage of time controlled ultraviolet drinking water processors being unable to use water during shutdown periods. It is a new generation of self-control equipment. This product has been obtained.
UV drinking water processorWorking parameters:
Processor model
|
Specifications
DNmm |
flow
m3/h |
working pressure
MPa |
supply voltage
V |
power
W |
Dimensions mm
Length x Width x Height |
remarks
|
DC1-30
|
15
|
0.7
|
≤0.6
|
220
|
30
|
1005×160×190
|
Threaded connection
|
DB3-30
|
40
|
4
|
≤0.6
|
220
|
90
|
1005×285×395
|
Threaded connection
|
DB4-30
|
50
|
8
|
≤0.6
|
220
|
120
|
1005×300×415
|
Threaded connection
|
DB6-30
|
65
|
16
|
≤0.6
|
220
|
180
|
1005×330×485
|
Flange connection
|
DB7-30
|
80
|
25
|
≤0.6
|
220
|
210
|
1005×340×475
|
Flange connection
|
DB10-30
|
100
|
30
|
≤0.6
|
220
|
300
|
1005×390×500
|
Flange connection
|
DB12-30
|
125
|
40
|
≤0.6
|
220
|
360
|
1005×420×505
|
Flange connection
|
DB14-30
|
125
|
50
|
≤0.6
|
220
|
420
|
1005×440×505
|
Flange connection
|
DB16-30
|
150
|
60
|
≤0.6
|
220
|
480
|
1005×460×505
|
Flange connection
|
DB18-30
|
150
|
80
|
≤0.6
|
220
|
540
|
1005×460×505
|
Flange connection
|
DB20-30
|
150
|
90
|
≤0.6
|
220
|
600
|
1005×480×505
|
Flange connection
|
DB24-30
|
150
|
100
|
≤0.6
|
220
|
720
|
1005×510×555
|
Flange connection
|
DB28-30
|
150
|
120
|
≤0.6
|
220
|
840
|
1005×520×565
|
Flange connection
|
DB32-30
|
150
|
150
|
≤0.6
|
220
|
960
|
1005×550×600
|
Flange connection
|
DB40-30
|
200
|
|
≤0.6
|
220
|
1200
|
1005×620×670
|
Flange connection
|
Note: Orders can be placed when the working pressure exceeds 0.6MPa.
The interface diameter can be produced according to user needs.
purpose
Small scale domestic water supply systems, variable frequency water supply systems, high-level water tanks and storage tanks in high-rise buildings, and various secondary water supply systems that use rivers, lakes, ponds, and well water as water sources can all use ultraviolet drinking water processors. So it is suitable for factories, troops, schools, stations, docks, airports, tourist attractions, beverage industries (such as beer, mineral water, and carbonated water), as well as hotels and restaurants for family use. Especially in summer, it is an ideal equipment for manufacturing refreshing drinks and artificial ice.
Puhui brand ultraviolet drinking water processorcharacteristic
① Compared with other methods, it does not change the physical and chemical properties of water, does not increase the odor and taste of water, and does not produce halogenated methane compounds,; Easy to operate and convenient to manage.
② Low voltage can start, 170V can start and the lamp does not flash, using electronic ballast does not require a starter.
③ There is a timing device that can detect the ultraviolet intensity of the lamp after 2000 hours of operation. When the illumination reaches the desired level, it can continue to be used to save money and allow for the efficient use of raw materials.
④ Optional timed automatic control device, which can set automatic startup and shutdown programs as needed. An additional flow sensor self-control device can be installed.
⑤ The shell material of the cylinder is made of SUS304 stainless steel plate, which is rust proof and has a long service life.
Processor model
|
Specifications
DNmm |
L1
mm |
L2
mm |
L3
mm |
W1
mm |
W2
mm |
H1
mm |
H2
mm |
φ
mm |
DC1-3O
|
15
|
1005
|
825
|
870
|
160
|
50
|
190
|
-
|
10
|
DB3-30
|
40
|
1005
|
740
|
860
|
285
|
100
|
395
|
190
|
10
|
DB4-30
|
50
|
1005
|
730
|
860
|
300
|
120
|
415
|
200
|
10
|
DB6-30
|
65
|
1005
|
730
|
860
|
330
|
140
|
485
|
250
|
10
|
DB7-30
|
80
|
1005
|
730
|
860
|
340
|
140
|
475
|
220
|
10
|
DBI0-30
|
100
|
1005
|
700
|
860
|
390
|
160
|
500
|
245
|
10
|
DB12-30
|
125
|
1005
|
700
|
860
|
420
|
190
|
505
|
240
|
10
|
DB14-30
|
125
|
1005
|
640
|
860
|
440
|
210
|
505
|
245
|
10
|
DB16-30
|
150
|
1005
|
640
|
860
|
460
|
230
|
505
|
245
|
10
|
DB18-30
|
150
|
1005
|
640
|
850
|
460
|
235
|
505
|
245
|
10
|
DB20-30
|
150
|
1005
|
640
|
850
|
480
|
255
|
505
|
245
|
10
|
DB24-30
|
150
|
1005
|
640
|
850
|
510
|
285
|
555
|
260
|
10
|
DB28-30
|
150
|
1005
|
640
|
850
|
520
|
295
|
565
|
265
|
10
|
DB32-30
|
150
|
1005
|
640
|
850
|
550
|
325
|
600
|
280
|
10
|
DB40-30
|
200
|
1005
|
640
|
850
|
620
|
395
|
670
|
315
|
10
|
Puhui brand ultraviolet drinking water processorInstallation precautions
① The selection of installation location should ensure that the pipeline through which water flows is not too long;
② The ultraviolet drinking water processor should be installed horizontally;
③ When selecting the installation location, there should be an operating space of ≥ 1.2 meters and ≥ 0.6 meters extending outward from both ends of the ultraviolet drinking water processor, respectively, for the purpose of replacing the ultraviolet lamp tube or maintenance work;
④ To monitor and control water flow, a flow meter can be installed simultaneously;
⑤ If a large water flow rate is required, multiple ultraviolet drinking water processors can be installed in parallel;
⑥ For the convenience of maintenance, a bypass pipe should be installed when installing the ultraviolet drinking water processor;
⑦ The indoor environment where the ultraviolet drinking water treatment device is installed has a relative humidity of no more than 89%, no corrosive gases, no conductive dust, and is not subjected to strong vibrations and impacts.
Operating Program for Hand Controlled UV Drinking Water Processor
① Close the inlet valve of the ultraviolet drinking water processor;
② Connect the power supply and turn on the power switch. At this time, the power indicator light and signal indicator light will turn on and ignite the ultraviolet lamp;
③ After being powered on for 3-5 minutes, open the inlet valve of the UV drinking water processor and start filling water;
④ Adjust the inlet valve to keep the water flow within the specified range;
⑤ If the signal light goes out during the process, it indicates that the corresponding ultraviolet lamp or circuit has a fault. At this time, the power supply and inlet valve should be turned off for maintenance;
⑥ When terminating the operation of the ultraviolet drinking water processor, the inlet valve should be closed first, and then the power should be turned off.
UV drinking water processorPrecautions for use
① When the water quality of the raw water does not meet the drinking water standards except for the academic indicators, other methods should be used to purify and meet the standards first. If the total amount of raw water exceeds 2000 per milliliter and the human gut microbiota exceeds 800 per liter, purification measures should also be taken first or the water flow rate should be reduced to achieve purification standards.
② When using or adjusting the timing device and flow sensor self-control device, the manual switch should be in the off state, otherwise the ultraviolet drinking water processor will work for a long time;
③ The flow self-control ultraviolet drinking water processor is adjusted by personnel. Before use, water should be supplied first and then the power should be turned on, otherwise the thermal sensitive component of the flow sensor will be damaged;
④ The working state of the ultraviolet drinking water processor with an alarm device is exactly opposite to that of the ordinary one. The normal working signal light is off, and when the ultraviolet light or circuit fails, the signal light is on and an alarm is triggered.
Maintenance rules
① When the ultraviolet drinking water processor is working, attention should be paid to observing the fluctuation range of the power supply voltage. When it is greater than 240V and less than 170V, voltage regulation or stabilization measures should be taken, otherwise it will affect the working life of the ultraviolet lamp;
② Staff should pay attention to the reading of the timer in order to regularly replace (according to the service life) new ultraviolet lamps. Due to the fact that low-pressure mercury ultraviolet lamps gradually lose their effectiveness as they approach their lifespan. If not replaced in a timely manner, the ultraviolet drinking water processor will no longer function;
③ Clean the quartz glass sleeve and inner wall of the cylinder once a year. When cleaning, first use a cotton cloth dipped in alcohol to wipe, then use a soft dry cloth to clean, and then wear clean gloves to install the quartz glass tube into the cylinder. Do not directly touch the surface of the cleaned quartz glass tube with your hands.
Puhui brand UV drinking water processor, provides free design and installation solutions Looking forward to your call: 0317-8294124