UV weather resistance test chamber test standard:
GB/T14522-93Artificial climate acceleration test method for plastics, coatings, and rubber materials used in mechanical industry products
GB/T16422.3-1997Plastic laboratory light source exposure test method: fluorescent ultraviolet lamp
GB/T16585-96Test method for artificial climate aging of vulcanized rubber (fluorescent ultraviolet lamp)
ISO 4892、ASTM G151、G154、D4329、D4587、D4799、SAE J2020
Application of UV weather resistance testing machine:
·The most widely used weather resistance testing machine in the world,Thousands of UV aging test chambers have been put into use worldwide.
The UV aging test chamber has become the world standard for laboratory accelerated weather resistance testing: compliant withISO、ASTM、DIN、JIS、SAE、BS、ANSI、GM、U.S.GOVTWaiting for standards and national standards.
·Quickly and realistically reproduce the damage caused by sunlight, rain, and dew to materials: in just a few days or weeks,Q8To reproduce the damage that takes months or years to occur outdoors, including fading
Discoloration, decreased brightness, powdering, cracking, blurriness, brittleness, decreased strength, and oxidation.
The reliable aging test data of the light aging test chamber can make accurate correlation prediction on the weather resistance (anti-aging) of products, and help to screen and optimize materials and formulas.
·Widely used in various industries, such as coatings, inks, paints, resins, plastics, printing and packaging, adhesives, automotive and motorcycle industries, cosmetics, metals, electronics, electroplating, pharmaceuticals, etc.
Characteristics of UV aging testing machine:
1The design of the UV aging box is completely based on the user's perspective, making it easy to operate, safe, and reliable.
2The installation thickness of the test piece can be adjusted, and the installation of the test piece is fast and easy.
3The upward rotating door does not hinder users from operating the equipment, and the UV aging test chamber only occupies a small space.
4The unique condensation system of the UV aging tester can meet the requirements by using ordinary tap water.
5The water heater is located under the container and does not soak in water. It has a long service life and is easy to maintain.
6The water level control is placed outside the UV box for easy monitoring.
7The equipment has casters for easy movement, and casters are standard accessories.
8Easy computer programming, automatic alarm for misoperation and malfunction. Programmable light intensity
9Calibration with an illuminance calibrator can extend the lifespan of the lamp (longer than1600Hour).
10There are instructions in both Chinese and English for easy reference.
11It is divided into ordinary type, light amplitude and illuminance control type, and spray type.
Technical standards:
1Compliant withISO、ASTM、DIN、JIS、SAE、BS、ANSI、GM、U.S.GOVTWaiting for standards and national standards
2The condensation device of the UV aging tester simulates the influence of outdoor humidity and can achieve100%The humidity
3Equipped with an electronic eye irradiance control system
4The UV box measures temperature accurately through a blackboard temperature sensor and can reproduce test results repeatedly
5Continuous cyclic testing of humidity, condensation, and water spray
6The illuminance hasCR-10Calibration Traceability and Automatic Calibration Procedure (USA)Q-LabPatent technology)
7Number of samples tested:75mm×300mmsample24block75mm×150mmsample48block
Product specifications and parameters:
model |
LK-UV1 |
LK-UV2 |
LK-UV3 |
|
function |
|
|
|
|
UV exposure |
√ |
√ |
√ |
|
condensation |
|
√ |
√ |
|
Irradiance display |
|
|
|
|
Irradiance regulation |
√ |
√ |
√ |
|
Water spray |
|
|
√ |
|
thermal shock |
|
|
|
|
Bar chart recorder |
(Optional) |
(Optional) |
(Optional) |
|
temperature range |
||||
UV temperature |
50-75℃ |
50-75℃ |
50-75℃ |
|
Condensation temperature |
40-60℃ |
40-60℃ |
40-60℃ |
|
volume |
137×53 ×135cm |
137×53 ×135cm |
137×53 ×135cm |
|
weight |
136kg |
136kg |
136kg |
|
Testing ability |
|
48Block template(75×150mm) |
48Block template(75×150mm) |
|
Power Supply and Power |
220V/50HZ1800W(Maximum) |
220V/50H2000W(Maximum) |
220V/50H2200W(Maximum) |
|
Water supply and consumption |
|
condensation:Tap water or distilled water approximately8rise/day |
condensation:Tap water or distilled water approximately8rise/Heavenly Spray:Distilled water or deionized water is approximately7rise/minute |
|
Lamp usage |
about24branch/year |
Depending on the irradiation time |
Depending on the irradiation time |
|
Warranty period (excluding lamp tube) |
1year |
1year |
1year |
|
Optional lamp tube models |
ImportUVB313L、UVA340Choose freely |
ImportUVB313L、UVA340Choose freely |
ImportUVB313L、UVA340Choose freely |
|
Optional lamp tube models:UVB313、UVA340. |
||||
remarks |
For the selection of light tubes,We offer importsUVA340,UVB313Lamp tube, in principleUVB-313The aging acceleration effect ratioUVB-340Faster and more obvious, but in terms of corresponding weather resistance test reproducibilityUVB-340To compareUVB-313Better. This depends on the urgency and strictness of the customer's experimental testing time. |
|||