Product Introduction
The IQ Sensor Net launched by WTW in Germany is an advanced online monitoring system that uses new testing technology for digitization. A single point multi parameter measurement system can be formed as needed, or a distributed multi-point multi parameter measurement system can be formed. IQ Sensor Net sensors are all digital sensors that output standard digital signals. They communicate with the central processing unit DIQ/S181, 282 through a 2-core shielded wire. The central processing unit displays measurement results, outputs 4-20mA signals or digital signals Modbus RTU/PROFIBUS DP, and relay contact outputs.
Technical Parameter
Model: DIQ/S282
Number of sensor connections: 1 or 2
Analog output: 1 or 2 sets of analog current (0/4-20mA), 3 sets of relays
Modbus RTU digital output: DIQ/S 282-MOD 3 sets of relays
Profibus DP digital output: DIQ/S 282-PR 3 sets of relays
Certification: ETL, cETL, CE
Electromagnetic compatibility: EN 61326, Class B; FCC Class A
Built in lightning protection: The entire system complies with EN 61326 enhanced overvoltage protection requirements
Wiring cable: IQ SENSOR NET cable SNCIQ or SNCIQ/UG (underground cable with PVC liner): 2-core shielded wire: 2 x 0.75 mm2;
Connection characteristics: All IQ modules transmit power and test signals simultaneously through 2-core shielded wires, enhancing EMC protection effect. There are multiple connection methods such as star, tree, streamline, or multi star, and the total cable length is up to 250 meters.
Transmission distance: 250 meters
Wireless transmission: Wireless transmission level 1, capable of transmitting up to 100 meters, with an additional 100 meters per wireless module, allowing up to 3 wireless transmission modules to be connected
Model: IFL700IQ
Test method: Ultrasonic echo measurement
Range: 0.4... 15.00 meters, can be converted to SLH sludge interface height or SLD sludge interface depth
Resolution: 0.01 m
Measurement accuracy: 0.1 m
Automatic cleaning: Scratch brush automatic cleaning
Surrounding environment: Working temperature: -5 ℃...+50 ℃
Storage: -25 ℃...+50 ℃
Permissible pH range for medium: 4... 12
Voltage resistance: 0.3 bar (including sensor cable)
Insertion depth: minimum 5cm, maximum 3m
Maximum flow velocity: 3m/s
Installation requirements: Vertical installation
Weight: 3.9Kg
Power consumption: 5.5 watts
Material: Sensor Rod/Head: Stainless Steel/POM/PVC-C Scraper: Grivory and Titanium Alloy
Signal output: digital signal
Connector: 2-core shielded wire, IQ specific connector
Input power supply: Maximum 24VDC, powered by IQ Sensor Net
EMI/RFI protection: EN61326, Class B, FCC Class A,