Multiple operating modes such as diffusion and pump suction are available for selection
Brief introduction
AmericaUniBestThe New Generation of Ubaida CompanyiGasTestPortable six in one composite toxic and harmful gas detector, suitable for includingEC、LEL、TC、PID、IRAll sensors, including those included, can be combined and configured flexibly. High detection accuracy, suitable for use in various hazardous environments.
2、 Product Features
1、 Gas monitoring instrument with graphical and menu driven operation
2、 Gas monitoring instrument with full-color graphic LCD display screen
3、 Color graphics display data clearly, the display interface can be personalized, displaying gas concentration and continuous danger trend graphics
4、 Can be equipped with an automatic management platform to calibrate and maintain instruments, throughinternetRealize networked data transmission, view data in real-time from different locations, and ensure timeliness
5、 “ventilation”Test mode
6、 User set parameters
7、 Run the instrument at startup or upon user request to determine whether it passes or fails
8、 Display results after testing
9Ventilation failure will automatically prompt calibration
3、 Main functions and advantages
1、 LCDdisplay
Function: Large screen black and white LCD display
Advantages: The large screen is convenient for reading instrument data, and the black and white display screen has better visual effects than the color screen in strong lighting conditions.
2sensor
Function: Exceeding30 A plug and play smart sensor, includingPIDInfrared(IR)Catalytic and electrochemical formulas.
Advantages: Various sensors can be combined and configured flexibly, with high detection accuracy, suitable for use in various hazardous environments.
3Three key operation
Function: Three key implementation for all functional operations
Advantages: The large buttons are easy to operate, less prone to misoperation, and can also be operated freely with protective gloves.
4Built in sampling pump
Function: Built in sampling pump
Advantages: Integrated design with built-in sampling pump for better performance and easy operation.
5Equipped with lithium battery and alkaline battery adapter
Function: Both lithium and alkaline batteries can be used as power sources
Advantages: In emergency situations, alkaline battery adapters can replace lithium batteries.
6display mode
Function: Display content with automatic layout and rotation
Advantages: The display screen can automatically layout according to the different numbers of sensors, achieving the desired font size for display; Built in gravity sensor, the screen can automatically rotate according to different grip positions,360°No dead corners, convenient for reading instrument readings.
7Data recording capacity
Function: Expanded data recording capacity
Advantages: Memory1Minute interval provided5Storage of readings from sensors, at least operational6Month time, storage interval1S-3600SAdjustable.
8Operating language and measurement units
Function: Supports both Chinese and English, with measurement units supportedppmandmg/m3
Advantages: Convenient for domestic users to use, while providing two mainstream gas concentration units.
9Alarm methods and types
Function: Support3Various alarm methods, including sound, light, and vibration alarms; provides3Alarm function for gas concentration exceeding the standard, instrument malfunction alarm, and personnel fall alarm
Advantages: Multiple alarm methods can effectively alert on-site personnel, provide personnel fall alarm function, and ensure the safety of on-site workers.
10Data communication method
Function: Supports data cable transmission and expandable wireless transmission
Advantages: Supports data cables andPCConnect and implement data export, instrument settings, and other operations through supporting software; Support wireless expansion function, wireless transmission distance can reach3Kilometers can receive real-time data from the site through a monitoring platform.
11Shell material and protection
Function: Stainless steel and protective rubber
Advantages: The shell is made of stainless steel and anti drop rubber sleeve, with high anti drop and protection level, and pump suction protection levelIP65Diffusion protection levelIP67.
4、 Standard configuration
1、 iGasTest 2Host (including sensors)/lithium battery/Alkaline battery adapter/Rubber protective cover
2、 Calibration adapter
3、 charger/PCcommunication adapter
4、 Data Cable
5、 Hexagonal tools and screwdrivers
6、 Data and software CD
7、 User manual, quick use guide
8、 Certificate of conformity, warranty card
9、 Pump suction also includes:PIDSensor cap disassembly tool, built-in pump, rotary buckle3 A hydrazine water filter
5、 Main parameters
1、 Sensor: Exceeding30 A plug and play smart sensor, includingPIDInfrared(IR)Catalytic and electrochemical formulas.
2、 Data: Memory1Minute interval provided5Storage of readings from sensors, at least operational6Month time, storage interval1S-3600SAdjustable; Supporting facilitiesPCSoftware that can store, analyze, and perform other operations on data.
3、 Operating language: Supports both Chinese and English, and users can choose the language type according to their needs.
4、 Measurement Unit: Supportedppmandmg/m3Two mainstream gas concentration units are provided.
5、 Display mode: The display screen can automatically layout according to the different numbers of sensors, so that the font can reach the ideal display size; Built in gravity sensor, the screen can automatically rotate according to different grip positions,360°No dead corners, convenient for reading instrument readings.
6、 Working temperature:-20℃to50℃Usually.
7、 Working humidity:0to95%Relative humidity (non condensing).
8、 Screen display: The large screen is convenient for reading instrument data, and the black and white display screen has better visual effects than the color screen in strong lighting conditions.
9、 Communication: Supports data cables andPCConnect and implement data export, instrument settings, and other operations through supporting software; Support wireless expansion function, wireless transmission distance can reach3Kilometers can receive real-time data from the site through a monitoring platform.
10Personnel protection: equipped with a fall alarm function to protect the safety of on-site workers.
11Alarm: Sound alarm(95dBredLEDAlarm light, vibration (users can configure all alarms).
12Power supply: Lithium ion batteries can support continuous operation of pump suction instruments for more than12Hour,4jointAAAlkaline batteries can support continuous operation time of pump suction instruments greater than6Hour. In special circumstances, longer usage time can be achieved through alkaline battery adapters.
13Protection level: diffusion typeIP65Pump suctionIP67.
14Size:193 x 96.5 x 66mm.
15Weight:880g.
16Optional hard portable case and extendable sampling probe (aluminum probe, can be extended up to)90cmInsulated handle,4.5mTeflon tube, leather cover).
6、 Main testing indicators
Targeted gas detection |
gas |
chemical formula |
measuring range |
accuracy |
The relevant standards for gas detection in confined spaces comply with the toxic and harmful protection standards for confined space operations as stipulated by the Ministry of Health |
combustible gas |
EX |
0-100%LEL |
1%LEL |
oxygen |
O2 |
0-30% VOL |
0.1%VOL |
|
carbon monoxide |
CO |
0-500ppm |
1ppm |
|
hydrogen sulfide |
H2S |
0-200ppm |
0.1ppm |
|
methane |
CH4 |
0-100% |
1% |
|
Testing for daily monitoring indicators of atmospheric environmental protection |
carbon dioxide |
CO2 |
0-5% VOL |
0.1%VOL |
hydrogen |
H2 |
0-1.00ppm |
2ppm |
|
nitric oxide |
NO |
250ppm |
0.5ppm |
|
nitrogen dioxide |
NO2 |
0-20ppm |
0.1ppm |
|
sulfur dioxide |
SO2 |
0-20ppm |
0.1ppm |
|
Designed for the frequency of occurrence of highly toxic substances, it is widely used for detecting toxic and harmful gases in chemical plants, steel plants, large warehouses, docks, and liquid containers |
hydrogen cyanide |
HCN |
0-50ppm |
0.5ppm |
chlorine |
Cl2 |
0-50ppm |
0.1ppm |
|
Hydrogen chloride |
HCl |
0-30ppm |
1ppm |
|
ammonia |
NH3 |
0-100ppm |
1ppm |
|
chlorine dioxide |
ClO2 |
0-1ppm |
0.03ppm |
|
phosphine |
PH3 |
0-20ppm |
0.1ppm |
|
ethylene oxide |
C2H4O |
0-10ppm |
0.1ppm |
|
Testing the total amount of organic compounds with irritating odors to ensure occupational health and safety |
VOC (Generally) |
PID |
0-1,000ppm |
1ppm |
7Emergency Environmental Protection Case
(1)Emergency monitoring of a sudden explosion accident in a chemical plant
1An explosion occurred during the production process of a certain chemical plant, causing casualties. The local environmental monitoring station's emergency monitoring is small
The team rushed to the scene to monitor the surrounding air quality.
2Emergency monitoring instrument: Multi gas emergency monitoring instrument(NH3,NO2,CO)
3Evaluation criteria:
Comprehensive Emission Standards for Air Pollutants(GB16297-1996)
Environmental Air Quality Standards(GB3095-1996)
Hygiene Standards for Industrial Enterprise Design(TJ36-79)
(2) Emergency monitoring of natural gas overflow accident in a certain thermal power plant
1An underground natural gas spill occurred in a thermal power plant, and the environmental monitoring center station activated emergency monitoring.
2Emergency monitoring instrument: Multi gas emergency monitoring instrument(SO2,H2S,CH4)
Multi gas emergency monitoring instrument(H2S,LEL,CO2,CO,CH4)
3Evaluation criteria:
Comprehensive Emission Standards for Air Pollutants(GB16297-1996)
Environmental Air Quality Standards(GB3095-1996)
Hygiene Standards for Industrial Enterprise Design(TJ36-79)
(3) Emergency monitoring of a freight train explosion accident
1A freight train carriage suddenly exploded, and the environmental monitoring station conducted an on-site investigation. The other carriages were destroyed
Good sealing.
2Emergency monitoring instrument: Multi gas emergency monitoring instrument(LEL,CO,SO2,H2S,Cl2,VOC).
3Evaluation criteria:
Environmental Air Quality Standards(GB3095-1996)
Hygiene Standards for Industrial Enterprise Design(TJ36-79)
(4) Emergency monitoring of odorous gases in streets of a certain city
1An abnormal odor appeared on a street in a certain city, and the emergency monitoring team of the environmental monitoring center station deployed monitoring points.
2Emergency monitoring instrument: Multi gas emergency monitoring instrument (for various toxic and harmful gases)VOC)
3Evaluation criteria:
Comprehensive Emission Standards for Air Pollutants(GB16297-1996)
Environmental Air Quality Standards(GB3095-1996)
Hygiene Standards for Industrial Enterprise Design(TJ36-7)