Product Details:
V230/V231 D12/D13Self operated pressure regulating valve
V230/V231 D12/D13 self operated pressure regulating valve (commander operated type), consisting of regulating valve, actuator, and commander, is an energy-saving product that does not require external energy and relies solely on the pressure changes of the regulated medium to automatically regulate pressure. It can be used as a pressure control device for non corrosive (maximum temperature 350 ℃) liquids, gases, steam and other media. Widely applicable to industrial sectors such as petroleum, chemical, metallurgical, and light industry, as well as urban heating and heating systems.
[Model and Specifications]
category
Pressure control regulating valve
Pre valve pressure regulating valve
Rear pressure regulating valve
hard seal
soft seal
hard seal
soft seal
model
V230 D13
V231 D13
V230 D12
V231 D12
Specifications
DN15-250
Technical parameters and performance indicators
Nominal diameter mm
15
20
25
32
40
50
65
80
100
125
150
200
250
Rated flow coefficient Kvs
3.2
5
8
12.5
20
32
50
80
125
160
320
450
630
Nominal pressure MPa
1.6 ; 4.0
Z value
0.6
0.6
0.6
0.55
0.55
0.5
0.5
0.45
0.4
0.35
0.3
0.2
0.2
Maximum working temperature ℃
V230 V231
Liquid ≤ 140; Gas ≤ 80
Hard seal V230
Isolation tank ≤ 200
Equipped with isolation tank and extension parts ≤ 300*
Equipped with isolation tank and heat sink ≤ 200
Pressure balancing component
bellows
Rolling diaphragm
Flange standard
DIA (flange standards can also be provided according to user requirements)
Valve body material
PN16: Cast iron (working temperature ≤ 200 ℃);
PN4.0: Cast steel, cast stainless steel (working temperature ≤ 350 ℃)Valve core material
stainless steel; The soft seal is made of stainless steel embedded with rubber rings
Maximum working pressure MPa
Nominal pressure (note the relationship between △ Pmax and working pressure and working temperature)
Note:
1. When the liquid temperature exceeds 140 ℃ and the gas temperature exceeds 80 ℃, the valve is inverted;
2. Z-value: Noise measurement coefficient, which is used to measure the magnitude of noise. For specific calculations, please refer to the selection guide for self regulating valves