VIP member
Product details
VC
PCB Transformer
A variant with dual output voltage, PRI 230 Vac, SEC 6 – 24 Vac, 3,2 – 16 VA
General data
Insulation material grade B
Validity up to 76%
The maximum ambient temperature is 40-60 ° C
Measure input voltage of 230 Vac
Measure power of 3-2-16 VA
Measure output voltage 6-2 x 24 Vac
Protection level IP 00
advantage
Ensure minimum specifications at high power
Self extinguishing mold material
Series or parallel connection is also suitable for dual output voltage
Durable corrosion protection, high insulation value, and extremely high electrical reliability brought by the use of mold resin mold XtraDenseFill
standard
The protection transformer complies with VDE 0570 Part 2-6, DIN EN 61558-2-6, EN 61558-2-6, IEC 61558-2-6, UL 5085-1/-2, CSA 22.2 No.66
The protection transformer complies with VDE 0570 Part 2-6, DIN EN 61558-2-6, EN 61558-2-6, IEC 61558-2-6, UL 5085-1/-2, CSA 22.2 No.66
license
VDE, UL 5085-1/-2, CSA 22.2 No.66
application
As a protective transformer used for safe electrical isolation of input and output terminals. By limiting the output voltage, this transformer is suitable for circuit construction of SELV and PELV.
As a power transformer used for matching voltage and simple electrical isolation.
PCB Transformer
A variant with dual output voltage, PRI 230 Vac, SEC 6 – 24 Vac, 3,2 – 16 VA
General data
Insulation material grade B
Validity up to 76%
The maximum ambient temperature is 40-60 ° C
Measure input voltage of 230 Vac
Measure power of 3-2-16 VA
Measure output voltage 6-2 x 24 Vac
Protection level IP 00
advantage
Ensure minimum specifications at high power
Self extinguishing mold material
Series or parallel connection is also suitable for dual output voltage
Durable corrosion protection, high insulation value, and extremely high electrical reliability brought by the use of mold resin mold XtraDenseFill
standard
The protection transformer complies with VDE 0570 Part 2-6, DIN EN 61558-2-6, EN 61558-2-6, IEC 61558-2-6, UL 5085-1/-2, CSA 22.2 No.66
The protection transformer complies with VDE 0570 Part 2-6, DIN EN 61558-2-6, EN 61558-2-6, IEC 61558-2-6, UL 5085-1/-2, CSA 22.2 No.66
license
VDE, UL 5085-1/-2, CSA 22.2 No.66
application
As a protective transformer used for safe electrical isolation of input and output terminals. By limiting the output voltage, this transformer is suitable for circuit construction of SELV and PELV.
As a power transformer used for matching voltage and simple electrical isolation.
| variant | Measure input voltage | Measure output voltage | measured power |
| VC 3,2/1/6 | 230 Vac | 6 Vac | 3,2 VA |
| VC 3,2/1/8 | 230 Vac | 8 Vac | 3,2 VA |
| VC 3,2/1/9 | 230 Vac | 9 Vac | 3,2 VA |
| VC 3,2/1/12 | 230 Vac | 12 Vac | 3,2 VA |
| VC 3,2/1/15 | 230 Vac | 15 Vac | 3,2 VA |
| VC 3,2/1/18 | 230 Vac | 18 Vac | 3,2 VA |
| VC 3,2/1/24 | 230 Vac | 24 Vac | 3,2 VA |
| VC 3,2/2/6 | 230 Vac | 2 x 6 Vac | 3,2 VA |
| VC 3,2/2/8 | 230 Vac | 2 x 8 Vac | 3,2 VA |
| VC 3,2/2/9 | 230 Vac | 2 x 9 Vac | 3,2 VA |
| VC 3,2/2/12 | 230 Vac | 2 x 12 Vac | 3,2 VA |
| VC 3,2/2/15 | 230 Vac | 2 x 15 Vac | 3,2 VA |
| VC 3,2/2/18 | 230 Vac | 2 x 18 Vac | 3,2 VA |
| VC 3,2/2/24 | 230 Vac | 2 x 24 Vac | 3,2 VA |
| VC 5,0/1/6 | 230 Vac | 6 Vac | 5 VA |
| VC 5,0/1/8 | 230 Vac | 8 Vac | 5 VA |
| VC 5,0/1/9 | 230 Vac | 9 Vac | 5 VA |
| VC 5,0/1/12 | 230 Vac | 12 Vac | 5 VA |
| VC 5,0/1/15 | 230 Vac | 15 Vac | 5 VA |
| VC 5,0/1/18 | 230 Vac | 18 Vac | 5 VA |
| VC 5,0/1/24 | 230 Vac | 24 Vac | 5 VA |
| VC 5,0/2/6 | 230 Vac | 2 x 6 Vac | 5 VA |
| VC 5,0/2/8 | 230 Vac | 2 x 8 Vac | 5 VA |
| VC 5,0/2/9 | 230 Vac | 2 x 9 Vac | 5 VA |
| VC 5,0/2/12 | 230 Vac | 2 x 12 Vac | 5 VA |
| VC 5,0/2/15 | 230 Vac | 2 x 15 Vac | 5 VA |
| VC 5,0/2/18 | 230 Vac | 2 x 18 Vac | 5 VA |
| VC 5,0/2/24 | 230 Vac | 2 x 24 Vac | 5 VA |
| VC 10/1/6 | 230 Vac | 6 Vac | 10 VA |
| VC 10/1/8 | 230 Vac | 8 Vac | 10 VA |
| VC 10/1/9 | 230 Vac | 9 Vac | 10 VA |
| VC 10/1/12 | 230 Vac | 12 Vac | 10 VA |
| VC 10/1/15 | 230 Vac | 15 Vac | 10 VA |
| VC 10/1/18 | 230 Vac | 18 Vac | 10 VA |
| VC 10/1/24 | 230 Vac | 24 Vac | 10 VA |
| VC 10/2/6 | 230 Vac | 2 x 6 Vac | 10 VA |
| VC 10/2/8 | 230 Vac | 2 x 8 Vac | 10 VA |
| VC 10/2/9 | 230 Vac | 2 x 9 Vac | 10 VA |
| VC 10/2/12 | 230 Vac | 2 x 12 Vac | 10 VA |
| VC 10/2/15 | 230 Vac | 2 x 15 Vac | 10 VA |
| VC 10/2/18 | 230 Vac | 2 x 18 Vac | 10 VA |
| VC 10/2/24 | 230 Vac | 2 x 24 Vac | 10 VA |
| VC 16/1/6 | 230 Vac | 6 Vac | 16 VA |
| VC 16/1/8 | 230 Vac | 8 Vac | 16 VA |
| VC 16/1/9 | 230 Vac | 9 Vac | 16 VA |
| VC 16/1/12 | 230 Vac | 12 Vac | 16 VA |
| VC 16/1/15 | 230 Vac | 15 Vac | 16 VA |
| VC 16/1/18 | 230 Vac | 18 Vac | 16 VA |
| VC 16/1/24 | 230 Vac | 24 Vac | 16 VA |
| VC 16/2/6 | 230 Vac | 2 x 6 Vac | 16 VA |
| VC 16/2/8 | 230 Vac | 2 x 8 Vac | 16 VA |
| VC 16/2/9 | 230 Vac | 2 x 9 Vac | 16 VA |
| VC 16/2/12 | 230 Vac | 2 x 12 Vac | 16 VA |
| VC 16/2/15 | 230 Vac | 2 x 15 Vac | 16 VA |
| VC 16/2/18 | 230 Vac | 2 x 18 Vac | 16 VA |
| VC 16/2/24 | 230 Vac | 2 x 24 Vac | 16 VA |
Product specification sheet download