Product details

Product Overview
Vicometo brandThe moisture analyzer uses a halogen lamp as the heating source, commonly known as a halogen moisture analyzer or halogen lamp moisture analyzer. The working principle of the Vicometo VM-5S is to inject halogen gases such as iodine or bromine into the bulb. Under high temperature, the sublimated tungsten wire reacts chemically with the halogen, and the sublimated tungsten will re solidify on the tungsten wire, forming a balanced cycle to avoid premature breakage of the tungsten wire. Therefore, halogen bulbs have a longer lifespan than incandescent bulbs. Meanwhile, due to the ability of the filament to operate at higher temperatures, higher brightness, color temperature, and luminous efficiency are achieved.Vicometo brandThe difference between VM-5S moisture analyzer and other products is that traditional moisture measurement generally uses oven drying method, which takes two to three or even three to four hours to test a sample, and also requires weighing with a balance and manual calculation to obtain the moisture value (moisture content) of the sample. The low efficiency of traditional oven method for moisture determination cannot meet the fast-paced production needs of enterprises.
Weike MeituoVM-5S uses an efficient drying heater - a high-quality ring halogen lamp - to quickly and uniformly heat the sample, and the moisture content of the sample is continuously dried. Throughout the measurement process, the rapid moisture analyzer automatically displays the measurement results in real-time, including sample weight, moisture content, solid content, measurement time, heating temperature, etc.
Vicometo brandThe VM-5S economical halogen moisture analyzer applies the principle of international oven drying method, and the measurement results have good consistency with the oven method moisture measurement, but the work efficiency is much higher than that of the oven method moisture measurement. The VM-5S economical halogen moisture analyzer is favored and praised by enterprise users for its ability to measure samples in just a few minutes.
Product Operation
instrument calibrationSteps:
First, assemble the card type moisture analyzer and connect it to the power supply. Turn on the power switch
Ø 1. Long press and hold "TAL" on VM-5S until "- cal 100-" is displayed
For other models, simply click the "Calibration" button on the interface to display cal 100
2. After placing 100g weights, click the calibration function button
Ø 3. Automatic calibration of instruments
Ø 4. Calibration completed with "100000" displayed, single point calibration completed
The linear calibration steps can refer to the instruction manual
Sample determination steps:
Ø 1. Cover the sampling cover with a heating hood
Ø 2. Set the required heating temperature in advance, such as "105 degrees Celsius"
Ø 3. After waiting for the numerical stability, press the "Start" button to start the measurement
Ø 4. The measurement is completed and the instrument displays the measurement results
The above measurement steps are for automatic shutdown mode testing. The instrument can use timed shutdown or set other heating temperatures. For the heating program, please feel free to contact us for a solution!
Product Features
Vicometo brandThe VM-5S economical halogen moisture analyzer has the following characteristics:
1. It can be used without installation, debugging, training or unpacking
2. Easy to operate, one click operation, automatic shutdown, quick determination of moisture and other values
3. The double-layer glass design of the heating chamber comprehensively protects the halogen lamp from damage caused by external forces, and the internal circulation effect formed by the double-layer glass improves the temperature control performance of the moisture meter, which is particularly outstanding in the determination of moisture in volatile substances
4. Visually transparent front window design, beautiful and elegant, allowing real-time observation of moisture changes during instrument operation
5. Multiple data display methods: moisture value, sample initial value, sample final value, measurement time, temperature initial value, temperature final value
6100 user-defined measurement methods, easy and fast storage and retrieval, no need to set each time
7. Imported materials and components, instrument stability, precision, and long service life are our eternal pursuit
8. The data processing CPU uses imported chips from the United States to ensure stable and accurate instrument calculations
9. The temperature control and sensing module has been upgraded, with faster heating and even temperature control
10. Brand new exterior design, imported raw materials with special formula integrated molding, truly resistant to high temperatures
11. Unique windproof design and anti electromagnetic radiation design protect the stability and accuracy of the instrument weighing system
12. RS232 serial port, expandable for computer communication, printer communication, PLC and network management
13. Choose original imported sensors from Germany and the United States for higher stability and rejection of temperature drift
14. Compliant with multiple national standards and American standards
Detailed specifications
| Product Model | VM-5S | VM-1S | VM-01S | |
| 称重精度 (d) | 0.005g | 0.001g | 0.0001g | |
| Moisture readability | 0.01% | 0.001% | ||
| Moisture range MC% | 0.00%-100.00% | 0.000%-100.000% | ||
| Solid content range DC% | 100.00%-0.00% | 100.000%-0.000% | ||
| Weighing range | 120g | |||
| load cell | German HBM | Electromagnetic force sensor (USA) | ||
| calibration method | External weight calibration (range calibration, linear calibration) | |||
| Repeatability (standard deviation) | Allow ≤ 3d (actual ≤ 1d) | |||
| Heating method | Halogen lamp heating | |||
| temperature sensor | PT-100 high-precision platinum rhodium temperature sensor | |||
| drying procedure | Standard heating, step heating, rapid heating | |||
| Heating range | 40-200℃ | |||
| Heating interval | 1℃ | |||
| Drying time setting | 1-99 minutes with a 1-minute interval | |||
| shutdown method | Timed, manual, automatic (shutdown under constant weight without water) | |||
| Measurement program | 100 sets of custom measurement programs | |||
| display parameters | Moisture value MC% Solid content DC% Sample total weight g Sample dry weight g Temperature ℃ Time trend curve | |||
| display mode | LCD large screen LCD backlit display | |||
| sample tray | 304 stainless steel sample tray Ø 90mm | |||
| Heating chamber height | 23mm | |||
| Sample visibility | Transparent visual window, allowing observation of internal sample changes | |||
| protective device | Halogen lamp protective tempered glass | |||
| Baud rate | 2400, 4800, 9600 | |||
| data communication | RS232 can connect to computers, printers, PLCs, etc | |||
| Print function | Optional printer (thermal, needle, adhesive, etc.) | |||
| Usage environment | 1-38 ℃ (ideal temperature of 18-25 ℃) | |||
| working power supply | Voltage 220V ± 10%, frequency 50HZ ± 1HZ (export can customize 110V power supply and power cord) | |||
| Host size (W * D * H) | 315mm*210mm*205mm | |||
| power supply voltage | 220V 50HZ maximum power 500W | |||
| weight | 3.9KG | 5.9KG | ||
| Instrument program | The instrument has two operating programs to choose from: optimized version (standard) and simplified version. The simplified version is easy to operate and eliminates some functions | |||
Application field
The VM-S series halogen moisture analyzer from the Vicometo brand is used in all industries that require rapid moisture measurement. It can measure any particle, powder, sheet, or non-volatile liquid, such as the pharmaceutical industry, chemical industry, electronics and semiconductor industry, plastic raw materials, rubber, tobacco, tea, food, starch, feed, coal, molding sand, sewage sludge, dairy industry, and more. The Vicometo VM-S series halogen moisture analyzer is an ideal choice for measuring moisture in the production process and laboratory of enterprises!
| General industry | Grain, wood, paper, textile, coal, ore, sand and gravel, soil, fertilizer, feed, chemical industry, tobacco |
| Inorganic salt powder | Calcium carbonate, refractory materials, talc powder, alumina, gypsum, desiccant, ceramic slurry, ceramic powder |
| food and drug | Traditional Chinese Medicine, Western Medicine, Health Food, Essential Oils, Dehydrated Foods, Food Fillings, Food Powder, Fruits and Vegetables, Dried Fruits, Noodles, Carbohydrates, Meat, Edible Oil, etc |
| Battery industry | Lithium battery powder, lithium battery slurry, battery grade sheet, graphene |
| Plastic and rubber industry | ABS, PP, PVB, PC, COC, BMC, DMC, SMC, BOPP, PBT plastic film, ESP Poly Long, PET plastic, PA polyamide LCP、PVC、 Recycled plastic, bottle flakes, PE polyethylene, rubber, PS styrene, EPE pearl cotton |
| solid content | Paint, milk soybean milk, glue, adhesive, rubber, slurry, mud, sludge, silica gel, chocolate, soy sauce, toothpaste, etc |
|
Our company has a series of moisture measurement technology solutions to support. Welcome to inquire about your exclusive moisture measurement solution! Solution Hotline: 400-7753-770 |
|
Precautions
The halogen moisture analyzer is used to measure the moisture and solid content in samples. Any other use may cause harm to individuals and damage to the instrument.Please read the instruction manual carefully before use and do not use it in environments that do not meet the requirements (such as electromagnetic force, wind, vibration, etc.)
Adequate space should be ensured around the instrument to prevent heat accumulation and overheating
Due to the heating unit around the instrument, the surrounding area may become hot. Do not place flammable materials around the instrument
After the test is completed, due to the fact that the sample itself, heating unit, and its container will still be very hot, caution should be taken when removing the sample
During the heating and drying process, the unconditional temperature of the circular heating will reach 400 ℃. Therefore, do not open or touch the heating unit. If you need to turn it on, please disconnect the power and wait until it completely cools down
For matrices containing toxic elements, they can only be heated and dried under well ventilated conditions, such as a fume hood
Samples that are prone to water absorption and moisture regain are recommended to be placed inside a vacuum glove box for operational testing