Introduction to WQ730 Water Turbidity Sensor
Simple, convenient, and easy to use
Ship grade cables
Durable anodized aluminum shell
Replaceable light source, debris protection
Technical parameters of WQ730 water turbidity sensor
|
output
|
4-20mA
|
measuring range
|
0-50NTU, 0-1000NTU
|
measuring method
|
Light scattering method
|
working voltage
|
10-36VDC
|
source current
|
30mA+sensor output
|
Warm-up time
|
5 seconds
|
operation temperature
|
-10~+50℃
|
material
|
306 stainless steel, polyoxymethylene resin, polyether sheathed cable
|
Maximum pressure
|
30psi
|
light source
|
Infrared LED, 880nm
|
Cable Length
|
Standard 7.5 meters, customizable up to 150 meters in length
|
Probe size
|
38mm diameter, 216mm in length
|
weight
|
454g
|
Standard configuration
|
DFJ000
|
WQ730 water turbidity sensor, 7.5-meter cable, user manual
|
DG0200
|
WQ770-B handheld turbidity meter, including WQ730 turbidity sensor, 7.5-meter cable, user manual
|
optional accessories
|
WQEXC
|
Extended cable, maximum length 150 meters
|
02-003
|
EPA certified first level turbidity standard, 0.0NTU, 1L, safe and non-toxic
|
02-004
|
EPA certified first level turbidity standard, 50NTU, 1L, safe and non-toxic
|
02-005
|
EPA certified first level turbidity standard, 100NTU, 1L, safe and non-toxic
|
02-006
|
EPA certified first level turbidity standard, 1000NTU, 1L, safe and non-toxic
|