1. This machine has temperature regulation, dehumidification, and humidification functions. Heating, cooling, dehumidification, and humidification. There are multiple functions such as ventilation, and users can choose any function according to their needs.
2. When indoor humid air passes through the surface of the evaporator, due to the evaporator temperature being lower than the dew point temperature of the humid air, water vapor in the air condenses and precipitates, accumulates in the water tray, and is discharged through the water pipe, reducing the moisture content of the air. After dehumidification, the humid air is heated by an air-cooled condenser, and its relative humidity decreases, thus achieving the goal of drying the ambient air.
3. Technical parameters:
performance model |
JH250 |
|||
empty transfer machine group whole machine sexually ability |
Refrigeration capacity |
kW |
250 |
|
104kcal/h |
21.50 |
|||
energy regulation |
% |
100,50,0 |
||
Heating Capacity |
electrical heating |
kW |
110 |
|
104kcal/h |
9.46 |
|||
Hot water heating |
kW |
215 |
||
104kcal/h |
18.49 |
|||
Steam Heating |
kW |
270 |
||
104kcal/h |
23.22 |
|||
Air volume |
m3/h |
46000 |
||
external static pressure |
Pa |
400/1000 |
||
Unit noise |
dB(A) |
77/84 |
||
Filtration efficiency |
High school effectiveness(colorimetry90-95%) |
|||
Temperature control range and accuracy |
℃ |
18~25℃,±0.5~1.0℃ |
||
Humidity control range and accuracy |
%RH |
RH50~70%, ±5%~10% |
||
power supply |
380V,50Hz, three-phase four wire system |
|||
Total capacity of the unit |
kW |
237.5-244.5 |
||
refrigeration system |
compressor |
type |
Fully enclosed vortex type |
|
quantity |
2 |
|||
Nominal input power(kW) |
67.1 |
|||
refrigerant |
type |
R22 |
||
Throttle method |
Thermal expansion valve |
|||
evaporator |
type |
Copper tube sleeve aluminum sheet |
||
condenser |
type |
Shell and tube type |
||
amount of watert/h |
55 |
|||
Inlet and outlet pipe diameterDN |
DN100 |
|||
wind machine system interconnected system |
fan |
type |
Low noise centrifugal type(belt transmission) |
|
quantity |
2 |
|||
power(kW) |
15.0-18.5 |
|||
air filter |
type |
initial effect+Medium efficiency |
||
add heat implement |
electrical heating |
type |
electrothermal |
|
power(kW) |
110 |
|||
Hot water heating |
Heating capacity(kW) |
215 |
||
Inlet and outlet pipe diameterDN |
40 |
|||
Steam Heating |
Heating capacity(kW) |
270 |
||
Inlet and outlet pipe diameterDN |
40 |
|||
humidifier |
type |
Electrode type/electrothermal |
||
Humidification amount(kg/h) |
42 |
|||
power(kW) |
30.4 |
|||
Inlet pipe diameter |
1/2” |
|||
External dimensions |
long(mm) |
3940 |
||
wide(mm) |
2200 |
|||
tall(mm) |
2500 |
|||
weight |
kg |
2750 |
Note: The data in square brackets are the parameters of the hood type unit
ZHONGYOUBasic configuration table of water-cooled constant temperature and humidity air conditioning unit
Serial Number |
Component Name |
Origin/Brand |
|
1 |
Fully enclosed compressor |
Copeland from the United States/Daikin from JapanDAIKIN |
|
2 |
water-cooled condenser |
Nanjing Jindian/Yangzhou 10000 |
|
3 |
Axial flow fan |
Zhejiang Dunli/Hangzhou Micro Light |
|
4 |
reservoir |
AmericaEmerson Emerson |
|
5 |
Finned evaporator |
self-made |
|
6 |
centrifugal fan |
Shandong Xinfeng/Zhejiang Yilida |
|
7 |
expansion valve |
Danfoss, Denmark/USAEmerson Emerson |
|
8 |
filter |
AmericaEmerson Emerson |
|
9 |
solenoid valve |
Castel Italy/Danfoss Denmark |
|
10 |
Pressure controller |
Changzhou White Egret/Shanghai Fengshen |
|
11 |
door plank |
Processing and manufacturing of imported equipment |
|
12 |
Electrical control components |
AC contactor |
Schneider TE, France |
Circuit breaker |
Schneider TE, France |
||
connecting terminal |
Honeywell in the United States and Phoenix in Germany |
||
controller |
Carel/Deep Blue Electronics from Italy |
notesThe component configurations listed in the above configuration table are the current standard configurations of our company. Our products will be updated at any time to keep up with the development needs of the times. If there are any configuration changes, please refer to the order contract. Customers can customize according to their specific requirements.
After sales Service Commitment Form
1 |
Warranty period, scope, and conditions |
The units provided by our company will provide warranty for the entire machine and the project from the date of acceptance1Annual service. During the warranty period, if the system cannot operate normally due to engineering and unit quality issues, our company guarantees free repair and replacement. |
2 |
Speed of problem-solving and troubleshooting |
Our company has professional technical personnel responsible for after-sales service. After receiving a repair call2Respond within hours,3Arrive at the scene within the day. |
3 |
Other commitments regarding after-sales service |
During the warranty period, our company will6Follow up with customers once a month. Beyond the warranty period, our company will charge reasonable repair costs. (Spare parts cost)+Travel expenses) x110% |
4 |
Other preferential conditions |
① Provide specialized tools and auxiliary materials required for installation and debugging. ② Our company will provide free technical consultation to users. |