brand | Other brands | typical configuration | Horizontal rotor centrifuge |
---|---|---|---|
Instrument functions | Ordinary centrifuge | Origin category | domestic |
Instrument type | tabletop centrifuge | Centrifugal grade | Large organelles/viruses |
Price range | 1-5 thousand | characteristic parameter | low speed |
application area | Medical and health, environmental protection, biotechnology, pharmaceuticals, comprehensive |
KH2500Microplate CentrifugeIt is an instant centrifuge specially designed for microporous plates, which facilitates the separation of hanging wall liquids. apply to96Kong or384And small capacity microporous plates, also suitable for skirts, without skirts, and various standardsPCRMicroplate.
When in use, the microplate can be vertically inserted into the centrifuge rotor from the top slot, and the liquid is kept at the bottom of the microplate under the action of surface tension, without leakage.
2、 Product Features
1Automatic shutdown when opening the lid
2Direct brushless motor
3Specially designed for microporous plates
① Applicable to96Kong and384hole
② Suitable for wearing skirts without skirts
③ Various standardsPCRMicroplate
Efficient: Fast acceleration, short braking time
3、 Application Fields
Microplate CentrifugeSuitable for centrifugation of samples in biochemistry, molecular biology, enzyme-linked immunosorbent assay, and general laboratory fields.
4Product parameters.
PRODUCT MODEL |
KH-2500 |
Speed setting range |
2200~2800 RPM |
time setting |
15second~1minute59second |
relative centrifugal force |
550g |
acceleration time |
≤10Second(0to2800 RPM) |
Brake Time |
≤4Second(2800to0 RPM) |
Opening time |
support |
Short run |
support |
capacity |
2Block standardPCRMicroplate |
Input power |
45W |
voltage |
AC110~220V/50-60HZ |
fuse |
250V/3A ∅5*20 |
External dimensions |
260*240*226mm |
weight |
3.3KG |
5、 Precautions
1Firstly, ensure that the instrument is placed on a horizontal workbench, press the lid button, and open the lid.
2Place two microplates vertically into the centrifuge tray.
3After installing the microplate, ensure that the orientation of the microplate is correct.
4If there is only one sample when using this instrument, it is necessary to take another sample of the same specification, add the same weight of solution (water can be used), seal it, and place it in the second rotating groove to ensure that the two rotating grooves are balanced.
5If the load weight on both sides of the rotor is different, it will cause the equipment to shake during operation and damage the equipment.