Product Overview
The SZ901SZ902 integrated wireless power diagram sensor is a continuous measurement of the tension and displacement data of the sucker rod within one cycle of the pumping unit, and ultimately forms a closed graph. Use this graphic to reflect the condition of the oil well. It is installed on the light pole, and the measured power diagram data is uploaded to the wireless gateway through a 2.4G network.
● Split type wireless power diagram sensor. The SZ907 wireless angular displacement sensor is used to measure the angle changes of the pumping unit (pump), and is usually used in conjunction with a wireless load sensor to measure the power diagram of low impulse oil wells and coalbed methane wells. The SZ908 wireless load sensor is used to measure changes in the load of the pumping unit (pump) and is used in conjunction with the SZ907 to form a success chart. Usually used for coalbed methane wells or oil wells with low impulse and small stroke.
The SZ903/SZ903D wireless pressure gauge and SZ905/SZ905D wireless temperature gauge are new sensors that integrate high-precision signal measurement, wireless RF, and routing networking technology. It can measure pressure signals of various media and transmit the signals to the wireless gateway module through a 2.4G network. It has the characteristics of no wiring, long working time, and investment savings.
The SZ904 wireless torque sensor is used to measure parameters such as torque, load, and speed of rotating devices (such as screw pump pumping unit well rotating light rod), and the collected signals are converted into digital signals for communication through 2.4G wireless network and wireless gateway.
Product Features
★ Adopting wireless data transmission method, it is convenient to install, easy to maintain, and improves the reliability of equipment operation. Compared with wired sensors, the installation cost of wireless sensors can be reduced by 90%.
★ Adopting a combination of disposable batteries or solar power supply, it is reliable and durable, and the battery level is monitored online to remind users to replace the battery in a timely manner, ensuring the availability of the equipment. Disposable batteries have low self consumption, large capacity, low failure rate, excellent price, and are easy to use for a long time. Solar power supply timely replenishes battery energy and reduces battery replacement cycles.
★ Adopting low-power design and precise power management technology. Further reduce product energy consumption and extend battery life.
★ Compliant with industry standards, with channel spread spectrum, compliant with IEEE802.15.4 wireless standard, using 2.4GHz universal frequency, can be subdivided into 16 channels, and direct sequence spread spectrum technology is used between channels to avoid interference and improve reliability
★ The scanning time of wireless sensors can be set according to production needs.
★ Protection level: IP65
Product Certification
Explosion-proof certification
(Image attached)
SZ901
product image |
parameter name |
technical indicators |
 |
Load measurement range |
0 ~ 50KN,0 ~ 150KN |
Load measurement accuracy |
± 0.5% F. S,± 1%F.S |
Displacement measurement range |
1 ~ 6m |
Displacement measurement accuracy |
± 1%F.S |
Range of impulse measurement |
2~6 times/minute |
lifespan |
20 million times within the range of 20% to 80% |
Wireless standards |
IEEE 802.15.4-2006@250kbps /Zigbee/WIA |
frequency |
2.4GHz |
transmission distance |
Communication distance 90m (open space) |
power supply method |
High performance lithium battery |
Battery replacement cycle |
2 years (collected once every hour) |
Equipment calibration cycle |
12 months (recommended) |
Installation method |
Horseshoe shaped fixed installation of suspension rope device at the wellhead of pumping unit |
Operating Temperature |
-40 ~ + 70℃ |
Operating Humidity |
5~95% RH without condensation |
Explosion-proof rating |
EX ib II C T3/T4 Gb |
SZ902
product image |
parameter name |
technical indicators |
 |
Load measurement range |
0 ~ 50KN,0 ~ 150KN |
Load measurement accuracy |
± 0.5% F. S,±1% F. S |
Displacement measurement range |
1 ~ 6m |
Displacement measurement accuracy |
±1%F.S |
Range of impulse measurement |
2~6 times/minute |
lifespan |
20 million times within the range of 20% to 80% |
Wireless standards |
IEEE 802.15.4-2006@250kbps /Zigbee/WIA |
frequency |
2.4GHz |
transmission distance |
Communication distance 90m (open space) |
power supply method |
Solar energy combined with high-performance lithium batteries |
Equipment calibration cycle |
12 months (recommended) |
Installation method |
Horseshoe shaped fixed installation of suspension rope device at the wellhead of pumping unit |
Operating Temperature |
-40 ~ + 70℃ |
Operating Humidity |
5~95% RH without condensation |
SZ907
product image |
parameter name |
technical indicators |
 |
measurement range |
-45° ~ +45° |
measurement accuracy |
0.5% F. S |
Wireless standards |
IEEE 802.15.4-2006@250kbps |
frequency |
2.4GHz |
transmission distance |
Communication distance 90m (open space) |
working power supply |
3.6V high-performance lithium battery |
Battery replacement cycle |
2 years (collected once every hour) |
Equipment calibration cycle |
12 months (recommended) |
Operating Temperature |
-40 ~ + 70℃ |
Operating Humidity |
5~95% RH without condensation |
Explosion-proof rating |
EX ib II C T3 Gb |
SZ908
product image |
parameter name |
technical indicators |
|
Load measurement range |
0 ~ 50KN |
Load measurement accuracy |
± 0.5% F. S,± 1% F. S |
lifespan |
20 million times within the range of 20~80% |
Wireless standards |
IEEE802.15.4-2006@250kbps /Zigbee |
frequency |
2.4GHz |
transmission distance |
Communication distance 90m (open space) |
power supply method |
High performance lithium battery |
Battery replacement cycle |
3 years (collected once every hour) |
Equipment calibration cycle |
12 months (recommended) |
Installation method |
Horseshoe shaped fixed installation of suspension rope device at the wellhead of pumping unit |
Operating Temperature |
-40 ~ + 70℃ |
Operating Humidity |
5~95% RH without condensation |
SZ903D
product image |
parameter name |
technical indicators |
 |
measurement range |
0~1Mpa/0~2Mpa/0~3.5Mpa/0~7Mpa/
0~10Mpa/0~20Mpa/0~35Mpa/0~70Mpa
|
measurement accuracy |
Level 0.5 |
measuring medium |
Crude oil, water, natural gas |
process connection |
M20 * 1.5 external thread |
Wireless standards |
IEEE 802.15.4-2006@250kbps /Zigbee/WIA |
frequency |
2.4GHz |
antenna form |
External antenna cap |
transmission distance |
Communication distance 90m (open space) |
Visual indication |
Monochrome LCD display |
power supply method |
High performance lithium battery |
Battery replacement cycle |
3 years (collected once per minute) |
Equipment calibration cycle |
12 months (recommended) |
Operating Temperature |
-40 ~ + 70℃ |
Operating Humidity |
5~95% RH without condensation |
Explosion-proof rating |
EX ib II C T3 Gb |
SZ903
product image |
parameter name |
technical indicators |
 |
measurement range |
0~10Mpa/0~20Mpa/0~35Mpa/0~70Mpa
0~1Mpa/0~2Mpa/0~3.5Mpa/0~7Mpa/
|
measurement accuracy |
0.2 level/0.5 level |
measuring medium |
Crude oil, water, natural gas |
process connection |
M20 * 1.5 external thread |
Wireless standards |
IEEE 802.15.4-2006@250kbps /Zigbee/VIA/Wireless HART |
frequency |
2.4GHz |
antenna form |
External antenna cap |
transmission distance |
Communication distance 90m (open space) |
Visual indication |
Monochrome LCD display |
power supply method |
High performance lithium battery |
Battery replacement cycle |
5 years (collected once per minute) |
Equipment calibration cycle |
12 months (recommended) |
Operating Temperature |
-40 ~ + 70℃ |
Operating Humidity |
5~95% RH without condensation |
Explosion-proof rating |
EX ib II C T3/T4 Gb |
SZ905D
product image |
parameter name |
technical indicators |
 |
measurement range |
-50 ~ + 150℃ |
graduation mark |
PT100 |
measurement accuracy |
Level 0.5 |
measuring medium |
Crude oil, water, natural gas |
process connection |
M27 * 2 external thread, insertion depth can be customized according to needs |
Wireless standards |
IEEE 802.15.4-2006@250kbps /Zigbee/WIA |
frequency |
2.4GHz |
antenna form |
External antenna cap |
transmission distance |
Communication distance 90m (open space) |
Visual indication |
Monochrome LCD display |
power supply method |
High performance lithium battery |
Battery replacement cycle |
3 years (collected once per minute) |
Equipment calibration cycle |
12 months (recommended) |
Operating Temperature |
-40 ~ + 70℃ |
Operating Humidity |
5~95% RH without condensation |
Explosion-proof rating |
EX ib II C T3 Gb |
SZ905
product image |
parameter name |
technical indicators |
 |
measurement range |
-50 ~ + 150℃ |
graduation mark |
PT100/PT1000 |
measurement accuracy |
0.2 level/0.5 level |
measuring medium |
Crude oil, water, natural gas |
process connection |
M27 * 2 external thread, insertion depth can be customized according to needs |
Wireless standards |
IEEE 802.15.4-2006@250kbps /Zigbee/VIA/Wireless HART |
frequency |
2.4GHz |
antenna form |
External antenna cap |
transmission distance |
Communication distance 90m (open space) |
Visual indication |
Monochrome LCD display |
power supply method |
High performance lithium battery |
Battery replacement cycle |
5 years (collected once per minute) |
Equipment calibration cycle |
12 months (recommended) |
Operating Temperature |
-40 ~ + 70℃ |
Operating Humidity |
5~95% RH without condensation |
Explosion-proof rating |
EX ib II C T3/T4 Gb |
SZ904
product image |
parameter name |
technical indicators |
 |
Load measurement range |
0~150KN |
Torque measurement range |
0~2000N. m |
Speed measurement range |
0~200 revolutions per minute |
Wireless standards |
IEEE 802.15.4-2006@250kbps /Zigbee/WIA |
frequency |
2.4GHz |
antenna form |
built-in antenna |
transmission distance |
Communication distance 90m (open space) |
power supply method |
High performance lithium battery |
Battery replacement |
Cycle of 3 years (collected once per minute) |
Equipment calibration cycle |
12 months (recommended) |
Operating Temperature |
-40 ~ + 70℃ |
Operating Humidity |
5~95% RH without condensation |
weight |
3KG |
Explosion-proof rating |
EX ib II C T3/T4 Gb |
Product Selection Sheet
Classification |
Product Name |
Functional Description |
remark |
Wireless instrument panel |
SZ901 |
Wireless power diagram sensor |
|
SZ902N |
Wireless power diagram sensor |
|
SZ903D |
Wireless digital pressure gauge |
|
SZ903 |
Wireless pressure sensor |
|
SZ904 |
Wireless torque sensor |
|
SZ905D |
Wireless digital thermometer |
|
SZ905 |
Wireless temperature sensor |
|
The naming of various models of wireless instruments is divided into the following two formats based on product characteristics:
1、 Format 1: SZ90X XXXXX, applicable to SZ901, SZ902, SZ902N, SZ903D, SZ904, SZ905D, SZ907, SZ908. The meanings represented by each part of the model are shown in the following figure:


For example, if the model is SZ901 3 4 3 2 3, it means that the range is 50KN, the accuracy is 1%, the wireless communication is Zigbee (four signal) mode, the hardware version is V1.8 (1611 chip), and the software version is a wireless load sensor that supports the four standardization protocol.
2、 Format 2: SZ90X XXXXXXXX, applicable to SZ903 and SZ905, the meanings represented by each part of the model are shown in the following figure:

Note: Pounds per square inch is a British unit, which is pounds per square inch. 1MPa=145psi, 1psi=6.895kPa

For example, if the model is SZ903 9 4 1 2 1 1 1 1 1 1, it means a gauge pressure transmitter with a range of 2.0MPa, accuracy of 0.5%, and wireless communication using Zigbee, with pressure units of MPa or kPa. The supported explosion-proof type is intrinsic safety explosion-proof, and the shell material is cast aluminum. It is powered by a 7.2V battery pack.
System organizational structure