overview
Environmental pollution has attracted close attention from governments and the public around the world,The call for protecting the ecological and atmospheric environment is increasingly growing. The main culprits causing atmospheric damage and pollution areCO2 andSO2Emissions.CO2、SO2Combustion of Automatic Power Fuel,The lower the sulfur content of gasoline, diesel, heavy oil, and other fuels used in vehicles, ships, and airplanes, the greater the reduction in air pollution. Both Europe and China have established a series of sulfur-containing standards,Restrict production and emissions.SO2It can also cause catalyst poisoning in the petrochemical industry,Causing harm such as acid rain in the atmosphere.
Our company produces X-ray fluorescence sulfur analyzer for detecting sulfur content in ship oilIt is a specialized product developed and manufactured to meet the needs of sulfur content detection in oil productsXFluorescence analyzer. It adopts the principle of energy dispersion,Integrated Micro Computer Design of Mechatronics,Analyze quickly and accurately. Its repeatability and reproducibility meet national standardsGB/T 17040andGB 11140Related requirements,It also fully complies with stricter American national standardsD 4294-03The requirements,It is used for detecting sulfur content in crude oil or petrochemical production processes,Provided important means. The instrument itself is green and environmentally friendly,Its price is only a fraction of that of imported instruments.
Main purpose
1.Measure the total sulfur mass percentage content in crude oil, petroleum, heavy oil, diesel, kerosene, gasoline, naphtha, and other oil products;
2.Measure coal chemical products,For example, the total sulfur content in primary benzene;
3.Measure the total sulfur or sulfide content in solid fine powder samples,Carbon materials such as anode carbon blocks, petroleum coke, modified asphalt, etc;
4. Measurement of total sulfur or sulfide content in lubricating oil and petroleum additives;
5.Measurement of total sulfur or sulfide content in other liquids.
Instrument characteristics
1.Microcomputer based design of instrument electromechanical integration,8Inch capacitive touch screen(1027*768)Display,No keyboard required,The operation interface is simple and beautiful;
2.Wide range of testing varieties,Wide detection range,Fast analysis speed,Low consumption of standard samples;
3.Using fluorescence intensity ratio analysis method,Automatic correction of temperature and air pressure,Hydrocarbon ratio(C/H)It can also be corrected;
4.Automatic diagnostic function of the instrument,Determine the working status and electrical parameters of the instrument;
5.Adopting one-time useMylarMembrane sample cup,Can avoid cross contamination;The sample cup is made using multifunctional pressing parts,Fast and convenient;
6.Accurate positioning of sample stage,It is very convenient to place samples and replace oil leakage prevention components,alsoAvoid the possibility of contamination of the detection system;
7.Large storage capacity of instrument data,Default Storage4096individualContent analysis results and8192Count measurement data,16The calibration result data of each instrument can be queried or accessed throughRS-232Upload standard serial communication port to computer;
8.The instrument hasAutomatic peak stabilization functionWhen the performance of the detector decreases, the system automatically adjusts the high voltage and corrects the error;
9.Instrument startup defaultAutomatically select working curveNo user intervention is required;
X-ray fluorescence sulfur analyzer for detecting sulfur content in ship oilSpecification
1.Sulfur measurement range: 7ppm~5%;
2.precision: arepeatability(r):<0.02894(X+0.1691); breproducibility(R):<0.01215(X+0.05555);
3.Sample size: two~3ml(Equivalent sample depth3mm~4mm);
4.Time: thirty、60、90、120、150second,Any setting;
5.Single sample automatic measurement,Measurement frequency: one、2、3、5、10Next arbitrary setting,Provide the mean and standard deviation at the end of the measurement;
6.The instrument can be stored10A calibration curve,
7.working conditions:temperature: five~35℃;relative humidity:≤ 85%(30℃);power supply: AC220V±20V、50HzRated power: 30W;
8.Size and Weight: 430mm×250mm×240mm; 10kg