XS-H3000 Three Channel Networked Workstation
Features and Functions:
1. The organic combination of chromatographic data processing and instrument operation control makes operation convenient and interface friendly;
2. Adopting 10/100M adaptive Ethernet communication technology; High communication speed, supporting long-distance data transmission and control; And one chromatography can be connected to three computers simultaneously;
3. Adopting multi-threaded technology to achieve simultaneous collaboration of signal acquisition, data processing, and user management;
4. The unique software architecture enables rich configuration of multiple monitoring agents in a system. Enable users with a limited number of instruments to view and manage analysis results on a single computer; Users with a large number of instruments can be equipped with multiple monitoring seats to meet the needs of multiple people working simultaneously;
5. The system supports simultaneous connection, control, and spectral processing of up to N GCs, greatly improving analysis efficiency.
6. Spectral peak intelligent identification technology minimizes the need for user set spectral processing parameters, and basically achieves peak detection, baseline correction, and overlapping peak segmentation
Automatic processing;
1. Sampling data can be read in from CDF files that comply with A/A (American Society for Analysis) standards, which can be integrated with chromatographic workstations such as Agilent and Waters;
2. Adopting a unique high fidelity digital filtering algorithm, it has strong anti-interference ability and can detect weak peaks of the same level as baseline noise;
3. There are six quantitative methods for data processing, including normalization, calibration normalization, single point correction (single point internal standard method, single point external standard method), and multi-point correction (multi-point internal standard method, multi-point external standard method), as well as seven working curve systems, including straight lines, broken lines, and index calculations
4. Design a 3-channel signal interface to facilitate the application of specialized workstations (such as power chromatography); The internal design baseline switching leveling technology achieves smooth docking of baseline switching.
5. Built in MODBUS/TCP and PROFIBUS protocols, the analysis results can be easily integrated into DCS, supporting user secondary development and functional expansion;
6. Equipped with an RS232 dedicated interface for reverse control, chromatography manufacturers can easily complete instrument reverse control;
7. Randomly equipped with an 8GU drive, it not only loads workstation software, user manual, video lectures, etc., but also facilitates your daily work
Technical indicators:
Input voltage range: three channels; ± 1.25V (or ± 2.5V) 2500V isolation
N Integral sensitivity: 0.05 μ V • s
Baseline noise: ± 1 μ V (at ± 1.25V)
Baseline drift: ≤ 3uV/h
Dynamic range: 10-7 μ V
Linearity: ± 0.005%
Repeatability: ± 0.005%
Sampling period: 10, 20, 40, 80, 160, 320 times/second adjustable
Communication interface 1:10/100M adaptive network port (for communication with workstations)
Communication interface 2: RS232 (communicates with other non network chromatography instruments to complete reverse control; Please call for consultation on relevant communication protocols
N Trigger sampling methods: interface mouse, shortcut keys, manual button, syringe automatic detection
Features and Functions:
1. The organic combination of chromatographic data processing and instrument operation control makes operation convenient and interface friendly;
2. Adopting 10/100M adaptive Ethernet communication technology; High communication speed, supporting long-distance data transmission and control; And one chromatography can be connected to three computers simultaneously;
3. Adopting multi-threaded technology to achieve simultaneous collaboration of signal acquisition, data processing, and user management;
4. The unique software architecture enables rich configuration of multiple monitoring agents in a system. Enable users with a limited number of instruments to view and manage analysis results on a single computer; Users with a large number of instruments can be equipped with multiple monitoring seats to meet the needs of multiple people working simultaneously;
5. The system supports simultaneous connection, control, and spectral processing of up to N GCs, greatly improving analysis efficiency.
6. Spectral peak intelligent identification technology minimizes the need for user set spectral processing parameters, and basically achieves peak detection, baseline correction, and overlapping peak segmentation
Automatic processing;
1. Sampling data can be read in from CDF files that comply with A/A (American Society for Analysis) standards, which can be integrated with chromatographic workstations such as Agilent and Waters;
2. Adopting a unique high fidelity digital filtering algorithm, it has strong anti-interference ability and can detect weak peaks of the same level as baseline noise;
3. There are six quantitative methods for data processing, including normalization, calibration normalization, single point correction (single point internal standard method, single point external standard method), and multi-point correction (multi-point internal standard method, multi-point external standard method), as well as seven working curve systems, including straight lines, broken lines, and index calculations
4. Design a 3-channel signal interface to facilitate the application of specialized workstations (such as power chromatography); The internal design baseline switching leveling technology achieves smooth docking of baseline switching.
5. Built in MODBUS/TCP and PROFIBUS protocols, the analysis results can be easily integrated into DCS, supporting user secondary development and functional expansion;
6. Equipped with an RS232 dedicated interface for reverse control, chromatography manufacturers can easily complete instrument reverse control;
7. Randomly equipped with an 8GU drive, it not only loads workstation software, user manual, video lectures, etc., but also facilitates your daily work
Technical indicators:
Input voltage range: three channels; ± 1.25V (or ± 2.5V) 2500V isolation
N Integral sensitivity: 0.05 μ V • s
Baseline noise: ± 1 μ V (at ± 1.25V)
Baseline drift: ≤ 3uV/h
Dynamic range: 10-7 μ V
Linearity: ± 0.005%
Repeatability: ± 0.005%
Sampling period: 10, 20, 40, 80, 160, 320 times/second adjustable
Communication interface 1:10/100M adaptive network port (for communication with workstations)
Communication interface 2: RS232 (communicates with other non network chromatography instruments to complete reverse control; Please call for consultation on relevant communication protocols
N Trigger sampling methods: interface mouse, shortcut keys, manual button, syringe automatic detection