Xuansheng Methane Non Methane Total Hydrocarbon Analyzer
After being filtered by a built-in filter, the methane non methane total hydrocarbon analyzer is collected into a quantitative ring. The samples in th
Product details

Xuansheng Methane Non Methane Total Hydrocarbon Analyzer  

 Methane Non Methane Total Hydrocarbon AnalyzerAfter being filtered by the built-in filter, the samples are collected into the quantitative ring. The samples in the quantitative ring are sent to the chromatographic column for separation through the action of carrier gas. The separated components are then sequentially detected by the FID detector to obtain accurate qualitative and quantitative analysis results.

  

Characteristics of methane non methane total hydrocarbon analyzer:

  

◆ Removable PTFE sample gas filter

◆ Built in air catalytic converter

◆ Built in data logger

The sample gas pressure regulator provides high stability sample gas flow rate

◆ Oxygen synergy function avoids the influence of flame temperature changes on measurement

  

  

Working principle of methane non methane total hydrocarbon analyzer:

  

Using external standard calculation method, the results are accurate and reliable. The sample is sucked into the quantitative ring by the pump, and the switching valve allows the sample to enter the chromatographic column with the carrier gas. Methane and non methane hydrocarbons are separated. When methane flows out of the chromatographic column and enters the detector for detection, the switching valve allows the carrier gas to blow back into the chromatographic column, causing the hydrocarbon compounds (non methane total hydrocarbons) in the column to form a peak and blow back to the detector for detection. This instrument can achieve online multi-point monitoring according to user needs.

Technical parameters:
Technical specifications of detector
Hydrogen flame ionization detector (FID)
★ Detection limit: Mt ≤ 8 × 10-12G/s (n-hexadecane-isooctane solution);
★ Baseline noise: ≤ 10μV
★ Baseline drift: ≤ 30μV/30min
★ Linear range: ≥ one hundred and six
Thermal conductivity detector (TCD):
★ Sensitivity: S ≥ 3500mV • ml/mg (benzene solution) (standard), high sensitivity 10000mV • ml/mg (equipped with electronic amplifier board, 2, 4, 8 times optional)
★ Baseline noise: ≤ 10μV
★ Baseline drift: ≤ 30μV/30min
★ Linear range: ≥ one hundred and four
Electron Capture Detector (ECD):
★ Detection limit: ≤ 1×10-14g/s
★ Baseline noise: ≤ 10μV
★ Baseline drift: ≤ 0.2mV/30min
★ Linear range: ≥ one hundred and three
★ Radioactive source: 63Ni
Xuansheng Methane Non Methane Total Hydrocarbon Analyzer
Flame photometric detector (FPD):
★ Detection limit: (S) ≤ 5 × 10-11g/s ,(P)≤1×10-12g/s;
★ Baseline noise: ≤ 10μV
★ Baseline drift: ≤ 0.2mV/30min
★ Linear range: ≥ 103(S),102(P)
Helium ionization detector (PDIHID):
★ Discharge mode: Pulse discharge
★ Baseline noise: ≤ 0.1mv
★ Baseline drift: ≤ 0.5mv/30min
★ Detection limit: ≤ 1.0×10¯10g/ml
Photoionization detector (PID)
★ Photon energy 10.6eV
★ Light source lifespan ≥ 3000h
★ Detection limit: ≤ 1ug/m3 (benzene)
★ Baseline noise: ≤ 8×10-14A
★ Linear range: ≥ 105
Instrument size: 470mm × 360mm × 220mm (length * depth * height)
Input power supply: AC220V DC12V 24V
Whole machine weight: 11KG (approximately)