Purpose: ZBW series landscape prefabricated substation (referred to as:Box transformer)It is a compact complete set of power distribution equipment that combines high-voltage electrical equipment, transformers, low-voltage electrical equipment, etc., and is used in urban high-rise buildings, urban and rural buildings, luxury villas, square parks, residential communities, high-tech development zones, small and medium-sized factories, mining and oil fields, and temporary construction sites. It is used for receiving and distributing electrical energy in the power distribution system, integrating the substation with the surrounding environment naturally.
Execution standards: The ZBW series landscape prefabricated substations comply with the relevant requirements of the standard IEC1330:1995 "High Voltage/Low Voltage Prefabricated Substations" and GB/T17467-1998 "High Voltage/Low Voltage Prefabricated Substations".
Structural features: The 12kVZBW prefabricated substation has the characteristics of strong completeness, small size, compact structure, safe and reliable operation, convenient maintenance, and mobility. Compared with conventional civil substations, box type substations of the same capacity usually occupy only 1/10~1/5 of the conventional substation, greatly reducing the design and construction workload and construction costs. In the distribution system, it can be used for ring network distribution systems, as well as for dual power or radiation terminal distribution systems. It is a new type of complete equipment for the construction and renovation of urban and rural substations.
Usage conditions: a、 The ambient air temperature shall not exceed+40 ℃ and shall not be lower than -25 ℃. The average temperature within 24 hours shall not exceed+35 ℃. b、 The altitude of the usage location shall not exceed 1500M. c、 The relative humidity of the surrounding air should not exceed 50% at a maximum temperature of+40 ℃, and a higher relative humidity is allowed at lower temperatures. (For example, 90% at+20 ℃) should take into account the possibility of occasional condensation due to temperature changes. d、 The inclination of the equipment during installation with respect to the vertical plane shall not exceed 5%. e、 The equipment should be installed in places without severe vibration and impact, as well as in places where electrical components are not susceptible to corrosion; The seismic intensity shall not exceed 8 degrees. f、 When users have special requirements, they can negotiate with the manufacturer to resolve them.
Product factory equipment: The manufacturer shall provide the following documents and attachments when supplying ◇ Packing list ◇ Product Qualification Certificate ◇ User Manual ◇ Factory test report ◇ Regarding electrical drawings Installation and use instructions for main components Cabinet door keys, operating handles, and spare parts specified in the contract.
Customer Ordering Notice: ◆ Full range of product models (including main circuit scheme number and auxiliary circuit scheme number) Main Circuit System Combination Sequence Diagram ◆ Electrical schematic diagram of auxiliary circuit ◆ List of components inside the cabinet ◆ System runtime sequence diagram. ◆ A floor plan of the switchgear is required. Other special requirements that do not meet the normal usage conditions of the product
Product performance:
|
Name Unit High voltage electrical equipment Transformer Low voltage electrical equipment Rated voltage kV1210/0.40.4 Rated current A630 100~2500 Rated frequency Hz505050 Rated capacity kVA 100~1600 Rated thermal stability current kA20/4S 30/1S Rated dynamic stability current (peak) kA50 63 Rated closing short-circuit current (peak) kA50 15~30 Rated switch breaking short-circuit current kA31.5 (fuse) Rated breaking load current A630 1min Power frequency withstand voltage kV to ground, phase 42, fracture 4835/28 (5 minutes) 2.0/2.5 Lightning impulse withstand voltage kV to ground, phase 75, fracture 8575 Shell protection level IP23DIP23DIP23DIP23D Noise level dB Oil transformer ≤ 55, dry transformer ≤ 65 Reactive power Compensation for Kuar |
|